Trouble Shooting / Technical Data - Migatronic FLEX 330XMA Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
TROUBLE SHOOTING
The wire feed has stopped
1. The inlet nozzle and the wire are not in align-
ment with each other.
2. The reel of wire is too taut, the wire must come
off the reel evenly.
3. The inlet tube or contact tip is badly worn or is
blocked.
4. The welding wire is not clean or it is rusty. It
could also be of an inferior quality.
5. The pressure roller has to be tightened.
Spatter
1. The wire feed is too fast for the voltage setting.
2. Worn out contact tip.
Porous weld. A cone is formed when spot
welding
1. Contact tip is blocked.
2. A leak in the gas hose draws in air which mixes
with the shielding gas.
The wire keeps sticking in the contact tip and
feeds very slowly
1. Any damaged wire should be cut off, pulled out
and replaced. The pressure on the wire feed
roller should be checked and adjusted if neces-
sary.
2. Worn out contact tip.
TECHNICAL DATA
We reserve the right to improve specifications and make
changes as necessary
Power source:
FLEX 330 S
Mains voltage
400 V ± 15%
Fuse
16 A
No load consumption
40 VA
Adaptor consumption
9.1 kVA
Mains current max.
19.8 A
Efficiency
0.85
Cos.phi
0.99
Open circuit voltage
80 - 85 V
100% duty cycle
250 A / 30.0 V
60% duty cycle
280 A / 31.2 V
45% duty cycle
330 A / 33.2 V
Current range DC
5 - 330 A
1
Protection class
IP 23
2
Sphere of application
Norm
EN60974-1
EN50199
Dim. lxbxh
72x28x54 cm
Weight, power source
57 kg
Torch cooling unit:
Primary voltage
Max. no load consumption
Cooling efficiency
Tank capacity
Max. flow
Max. pressure
1
Protection class
Dimensions
Weight (excl. cooling liquid)
1
Equipment marked IP23 is designed for indoor and outdoor applications
2
S
The machine meets the standards which are demanded of machines
working in areas where there is an increased risk of electric shock
14
FLEX 400 S
FLEX 500 S
400 V ± 15%
400 V ± 15%
20 A
32 A
40 VA
40 VA
12.5 kVA
24.8 kVA
25.7 A
44.9 A
0.85
0.85
0.99
0.99
80 - 85 V
90 – 95 V
300 A / 32.0 V
400 A / 36.0 V
350 A / 34.0 V
450 A / 38.0 V
400 A / 36.0 V
500 A / 40.0 V
5 - 400 A
5 - 500 A
IP 23
IP 23
S
S
EN60974-1
EN60974-1
EN50199
EN50199
72x28x54 cm
72x28x54 cm
57.7 kg
57.7 kg
MCU 1250
400 V ±15 %
5 W
1250 W
4 liters
1.75 l/min - 1.2 bar - 60°C
2.5 - 3.0 bar
IP 23
70x30x22 cm
16 kg
S