Technical Data - Migatronic FOCUS TIG 160 DC HP PFC Manuel D'instruction

Masquer les pouces Voir aussi pour FOCUS TIG 160 DC HP PFC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Gas connection
Connect the gas hose, which branches off from the back panel of
the welding machine (6), to a gas supply with pressure regulator (0-
8 bar). (Note: Some types of pressure regulators require an output
pressure of more than 2 bar to function optimally). Fit and secure
the gas hose to the gas connection (7) on the front of the machine.
Usage of the machine
When welding, a heating of various components of the machine
takes place and during breaks these components will cool down
again. It must be ensured that the flow is not reduced or stopped.
When the machine is set for higher welding currents, there will be a
need for periods during which the machine can cool down.
The length of these periods depends on the current setting, and the
machine should not be switched off in the meantime.
If the periods for cooling down during use of the machine are not
sufficiently long, the overheating protection will automatically stop
the welding process and the yellow LED in the front panel will come
on. The yellow LED switches off when the machine has cooled
down sufficiently and is ready for welding.
Connection of electrode holder for MMA
The electrode holder and return current cable are connected to plus
tap (4) and minus tap (3). Observe the instructions from the
electrode supplier when selecting polarity.
Static characteristic
Static Charateristic
100
90
80
70
60
50
40
30
20
10
0
0
40
Focus Tig 160 DCHP PFC
MMA Load line
TIG Load Line
80
120
160

TECHNICAL DATA

Power source:
Mains voltage ±10% (50Hz-60Hz)
Minimum generator size
Fuse
Mains current, effective
Mains current, max.
Power, 100%
Power, max.
Open circuit power
Efficiency
Current range TIG
Current range MMA
Permitted load:
100% (40° ambient temp.)
60% (40° ambient temp.)
35% (40° ambient temp.)
30% (40° ambient temp.)
Open circuit voltage
Electrode diameter
Extension cable
Slope down
Gas post-flow
TIG-ignition
1
Application class
2
Protection class
Standards
Dimensions (LxWxH)
Weight
I2 [A]
S The machine meets the standards which are demanded of
1
machines working in areas where there is an increased risk
of electric shock
2
Equipment marked IP23S is designed for indoor and outdoor
applications
13
FOCUS TIG 160
DC HP PFC
1x230 V
9.5 kVA
16 A
12.9 A
23.1 A
2.7 kVA
6.3 kVA
280 W
0.9
10-160 A
10-160 A
MMA
TIG
100 A
110 A
110 A
130 A
160 A
160 A
75 V
1.6 - 3.25 mm
min. 2.5 mm²
0 - 10 secs
0 - 30 secs
HF/LIFTIG
S
IP23S
EN/IEC60974-1
EN/IEC60974-3
EN/IEC60974-10
47x18x25 cm
10.7 kg

Publicité

Table des Matières
loading

Table des Matières