Technical data
POWER SOURCE
Mains voltage ±15% (50-60Hz), V
- Autotransformer
optional ±15% (50-60Hz, V
Minimum short-circuit power Ssc, MVA
1
Fuse, A
Mains current, effective, A
Mains current, max., A
Power, (100%), kVA
Power, max., kVA
Power, open circuit, W
Efficiency
Power faktor
Current range, A
Duty cycle
100%
20°C, A/V
Duty cycle
60%
20°C, A/V
Duty cycle
100%
40°C, A/V
Duty cycle
60%
40°C, A/V
Duty cycle
max.
40°C, A/%/V
Open circuit voltage, V
Sphere of application
2
3
Protection class
Standards
Dimensions (HxWxL), mm
Weight, kg
Wire feed speed, m/min
WIRE FEED UNIT MWF 27
2
Wire feed speed, m/min
Torch connection
Wire-reel diameter, mm
100% duty cycle 40°C, A/%
Max. duty cycle, 40°C, A/%
Wire diameter, mm
3)
Protection class
Gas pressure max., MPa (bar)
Dimensions (HxWxL), mm
Weight, kg
Standards
1)
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc of the grid at the interface point is greater than or equal to the stated data
in the abovementioned table. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to the stated data in the abovementioned table.
2)
S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks
3)
Equipment marked IP23 is designed for indoor and outdoor applications
18
OMEGA
OMEGA
2
2
300
300 Boost
3x400
3x230-400. 1x230-400
-
-
0.8 (1x230). 2.1 (3x230). 2.1 (3x400)
10
16
7.6
11.9 (1x230). 7.0 (3x230). 3.1 (3x400)
15.3
45.3 (1x230). 26.7 (3x230). 15.0 (3x400)
5.3
2.7 (1x230). 3.8 (3x230). 3.5 (3x400)
10.4
10.4 (1x230). 11.0 (3x230). 10.3 (3x400)
20
30
0.88
0.84(1x230). 0.84 (3x230). 0.87 (3x400)
0.93
0.99 (1x230). 0.95 (3x230). 0.95 (3x400)
15-300
15-300
230/25.5
170 (1x230) 200 (3x400)
245/26.3
220/25 (1x230) 235/25.7 (3x400)
175/22.8
110/19.1 (1x230) 135/21.0 (3x400)
195/23.8
135/20.8 (1x230) 170/22.5 (3x400)
300/24/29.0
300/15/29.3 (1x230) 300/24/28.9 (3x400)
52
55
S/CE
S/CE
IP23
IP23
EN/IEC60974-1. EN/IEC60974-5. EN/IEC60974-10
550x250x640
550x250x640
26
28
1.5-18
1.5-18.0
COOLING UNIT
0.5-27.0
Cooling efficiency, W
EURO
Tank capacity, liter
300
Flow, bar - °C - l/min
430/100
Pressure max., bar
550/50
Standards
0.6-2.4
IP23
0.5 (5.0)
470x210x690
13
EN/IEC660974-1.
EN/IEC660974-5.
EN/IEC660974-10
OMEGA
2
400
3x400
3x230-500
4.0
20
17.5
26.0
12.1
18.0
40
0.85
0.94
15-400
MIG
MMA
335
335
400
400
300/29.0
300/32.0
370/32.5
350/34.6
400/50/34.0
400/45/36.0
70
S/CE
IP23
EN/IEC60974-1. EN/IEC60974-5 (C). EN/IEC60974-10.
530x250x650 (C) /
1400x510x1020 (S)
36.5 (C) / 84 (S)
0.5-27.0
EC DECLARATION OF CONFORMITY
1100
3.5
1.2 - 60 - 1.75
3
hereby declare that our machine as stated below
EN/IEC60974-2
Type: OMEGA
As of week 02 2013
conforms to directives:
European standards:
Issued in Fjerritslev on 7 January 2013.
OMEGA
2
550
3x400
3x230-500
5.74
35
27.3
39.2
18.9
27.1
30
0.91
0.94
15-550
MIG
MMA
475
475
550
550
430/35.5
430/37.2
510/39.5
510/40.4
550/50/41.5
550/50/42.0
80
S/CE
IP23
630x250x650 (C) /
1400x510x1020 (S)
37.5 (C) / 85 (S)
0.5-27.0
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
2
2006/95/EC
2004/108/EC
2011/65/EU
EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Anders Hjarnø Jørgensen
CEO