Low Voltage; Overvoltage; Overheated; System Error - Hürner HST300 Print+ Manuel De L'utilisateur

Poste de soudage universel
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str.
35325 Mücke, Germany

11.1.3 Low Voltage

The input voltage is below 190 volts. Adjust generator output voltage.

11.1.4 Overvoltage

The input voltage is over 285 volts. Decrease generator output voltage.

11.1.5 Overheated

The transformer temperature is too hot. Let the welding unit cool down
for about 1 hour.

11.1.6 System Error

CAUTION!
The unit has to be disconnected immediately from the power supply and
the fitting. The auto-test has found a system error. The unit must no longer
be used and has to be sent to an authorized shop for check and repair.

11.1.7 Temperature Error

The ambient temperature measured is outside the operating range of the
welding unit, i.e., below –10°C or over +50°C.

11.1.8 Temperatur Sensor Defective

The ambient temperature sensor on the welding cable is damaged or
defective.

11.1.9 Clock Error

The internal system clock works improperly or is defective. Reset the clock
or send the welding unit to the manufacturer for check and service.

11.1.10 Next Service Due

The recommended next service date for your welding unit has passed.
The "Next Service Due" message has to be reacted to by pressing the
START key. Please send the welding unit to the manufacturer or an au-
thorized service point for service and check-up.

11.1.11 Input Error

A code entered is incorrect. With manual input enabled, no welding time
was set. An incorrect range was selected in the date setting.

11.1.12 Memory Full

The system memory is full of welding reports. Print off the reports in
memory or switch memory control off, using the operator card. The oldest
report will then be overwritten.

11.1.13 Printing interrupted

During data transfer or printing, an error condition occurred and could
not be cleared.

11.2 Errors During Welding

All errors that occur while welding is in progress are also indicated by
an audible alarm.
11.2.1 Low Voltage
The input voltage is below 190 volts. The welding device triggers the
audible alarm. If the error condition persists for longer than 15 seconds,
the welding process will abort. If the voltage goes down below 175 volts,
the welding process will be aborted immediately.
16
HST300 Print+ User's Manual
Version February 2009
EN

Publicité

Table des Matières
loading

Table des Matières