The time of day and the date can be set using the keypad. The portions
"Hour," "Minute," "Day," "Month," and "Year" are set separately.
Press the START/SET key to confirm your settings.

9.1.3 Setting the Buzzer Volume

When the "Set Volume" sub-menu was selected, the screen changes
and the display reproduced in Display 14 appears. The buzzer can also
be heard. Turn the buzzer volume up or down to the desired value
using the ï, ð arrow keys (from 0 to 100) and confirm your setting
by pressing the START/SET key.
9.2

Understanding the "Recording" Sub-menu

"Welder Code on" means that the welder identification code has to
be entered as set with "Welder Code Options," "off," that this
is impossible.
"Commission Number on" means that the commission number (job
number) will have to be entered or confirmed before every new
welding, "off" that the user is not prompted to enter it.
All data can also be read from a bar code with the scanner,
provided such a bar code is available.
Info
10

Self-Monitoring Functions Overview

10.1 Errors During Data Input

10.1.1 Code Error

An erroneous input has occurred, a code tag is poor or has an error
in code symbology or code reading was improper.

10.1.2 No Contact

There is no properly established electric contact between the welding
unit and the fitting (check push-on terminal on fitting), or the heater
coil is defective.

10.1.3 Low Voltage

The input voltage is below 175 volts. Adjust generator output volt-
age.

10.1.4 Overvoltage

The input voltage is over 290 volts. Decrease generator output volt-
age.

10.1.5 Overheated

The transformer temperature is too hot. Let the welding unit cool
down for about 1 hour.

10.1.6 System Error

CAUTION!
The welding unit has to be disconnected immediately from both the
power supply and the fitting. The auto-test has detected an error in
the system. The unit must no longer be operated and has to be sent
to an approved shop for check and repair.
14
EN
HÜRNER HST 300 Print 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Date/Time
21.06.13
Buzzer Volume
< ------20-------- >
** Data Recording **
Welder Code
>Commission No.
14:28
Display 13
Display 14
on
on
Display 15
Version June 2013