DISPLAY SIGNAL AND ERROR TABLE
During normal mode, some errors could occur that are described in table 2. The error code
is shown on the display. Some errors prevent some machine automatisms from being used
(i.e. errors E00 and E01) or cause them to stop early (i.e. error E11).
Pressing the Clear key on the control panel cancels the error code on the display but if
the cause of the error is not removed and the command that generated it is repeated,
the message will reappear.
ERROR #
MEANING
E00
No calibration data
E01
No signal on analogue channel
#1 (radial movement measure-
ment potentiometer).
E02
No signal on analogue channel
#2 (channel currently not used)
E03
No signal on analogue channel
#3 (channel currently not used)
E04
No signal on analogue channel
#4 (analogue laser for the Side
To Side)
E05
Not used
E10
E11
No signal on digital channel #1
(chain ring counting proximity
switch)
Table 2 – Errors and actions to be performed
Normally the numbers or messages shown on the display are fixed, but they may flash in
some cases.
As a general rule, which is valid for all operating modes, the following applies:
when the numbers and/or messages flash, this means that the displayed value must be
confirmed by the operator or that an operator action is required.
90
ACTION
Calibrate the machine. If the error
remains replace the board CPU-RX2.
This signal appears also when a
new board is installed.
Check the connection of the
potentiometer and its condition.
If the error persists contact tech-
nical assistance.
Check the connection of the laser
and its condition. Check that the
glass on the front of the laser is
not dirty. If the error persists con-
tact technical assistance.
Check the connection of the prox-
imity switch and its condition.
- English - Operator's manual