Separator removal and cleaning
1
Using thumb and index finger grip the tab of the
separator and pull forwards.
4
Clean water tank outlets
1
B
A
Make sure the clean water tank is empty.
Unscrew the two clean water outlets, A
and B.
Regular Maintenance
2
Lift the separator away from the tank.
5
Once the separator has been removed, wash thoroughly under a
tap making sure to run water through the tubes and to clean the
grid filter (A).
Once clean thoroughly check the rubber seal for any damage or
cracks (B).
If any damage or cracks are found on the rubber seal replace
A
the separator. Failure to replace could cause loss in suction and
machine performance.
2
Remove the clean water outlets from the
clean water tank.
37
37
3
Take the separator to a suitable cleaning station.
3
Wash the clean water outlets thoroughly
under a tap, make sure the filter is clean
with no blockages. Check for any damage
(if any damage is found replace the clean
water outlets).
B