Float valve removal and cleaning
1
A
To remove the float valve twist the red retainer clip in
the direction shown by the arrow on the retainer clip.
5
Tilt forwards at a slight angle making sure the protruding nub fits into the recess on the float valve (B).
Press down firmly on the arrow and the float valve will click into place.
!
WARNING! DO NOT PULL ON THE FLOAT BALL (A)
PULLING ON THE FLOAT BALL WILL CAUSE IT TO BREAK AND THE VACUUM SHUT OFF
Emptying tanks
1
When finished using the machine it is good practise to empty and clean the tanks of the machine.
To do this firstly remove the tank assembly from the machine ( see set up ),
1. Remove the clean water tank from the main tank body and empty.
2. Remove the separator from the tank.
3. Pick up the tank, use the base shown as a handle, tip the contents into a suitable drain, rinse the tanks and repeat the emptying
process. Refit the clean water tank and separator and place back onto the machine.
Note: If the machine is to be left for long periods between use, ensure the clean water tank is emptied.
2
A
Lift the float valve from the tank,
wash and inspect for damage.
B
2
Regular Maintenance
3
A
WILL FAIL.
41
41
4
Place the float valve back down into
the tank.
3
!