To modify the temperature user just needs to press the keys 1 to 3 in order to have
them ON or OFF. Standard setting must be 93ºC.
•
This may be done on each control panel.
•
To finish and exit, press key 5 in group 1 for 5 seconds. All buttons will go OFF,
then press key 3 on group 1 to get into working mode.
b.
Configuration of the steam boiler temperature. This must be done at the same
time than the group temperature setting. Default setting is 125ºC, and in order to
modify it group 1 and group 2 control panels must be used as follows:
•
Get into the setting mode (press key 5 + 3) in group 1.
•
Key 5 is FLASHING in all control panels. It is important that this happens in all
groups, so we can modify each temperature accordingly.
•
Temperature may be showed as follows:
•
To modify the temperature user just needs to press the key 4 on groups 1 and 2 in
order to have them ON or OFF.
•
To finish and exit, press key 5 in group 1 for 5 seconds. All buttons will go OFF,
then press key 3 on group 1 to get into working mode.
c.
Functions being activated through control panel without getting into setting
menu:
•
Automatic cleaning – Press keys 5 + 1 on each coffee group
•
ON/OFF coffee groups – Press keys 5 + 2 on each coffee group. 5 keys will be
OFF while group is OFF. To activate again, repeat the same process.
•
Pre-infusion activation – Press keys 5 + 4 on each coffee group, activating a fixed
3 second pre-infusion time. To deactivate again, repeat the same process.
•
Economy mode (CE parameter management), adjusted through group 1
keyboard:
1. CE=5 (default setting) - With the machine OFF, press key 1, and switch ON the
machine. Key 1 will be ON. Switch OFF and ON machine again to come back to
working mode.
24
MAN.31 V13 MANUAL BARISTA T 2023_EN_ES_DE_FR.indd 24
MAN.31 V13 MANUAL BARISTA T 2023_EN_ES_DE_FR.indd 24
GROUP 1
GROUP 2
KEY 4 (L2)
KEY 4 (L2)
OFF
OFF
120ºC
ON
125ºC
OFF
130ºC
ON
OFF
OFF
ON
ON
18/10/2023 11:23:27