13 - Specific functions of ONE and PLUS models
The Barista T ONE and Barista T PLUS models have 2 independent displays on each
of the group keypads through which we can control the following parameters.
Parameter Description
Tx
Setpoint temperature of group X (x = 1,2,3), shown on the left screen
during the operation of the machine.
Tc
Temperature of the steam boiler
Ud
Units of measure: Degrees Celsius (C) or Farenheit (F)
TEC
Sub-menu with temperature control configuration parameters, including P /
I / d / b / Ce / Sen / dSP
P/I/d/b
Configuration parameters of the PID temperature control.
Ce
Power configuration parameter. Depending on this parameter (number
between 1 and 6) we indicate to the machine how many resistors can
work at the same time, always prioritizing those of the coffee groups. See
power limitation table to see the different options in section 5 - electrical
connection.
SEn
It allows modifying the sensitivity of the level probe, as follows: Lou (Low
sensitivity, 150 kΩ) / Mid (medium sensitivity, 400 kΩ) / hig (high sensitivity,
1 MΩ)
dSP
Allows to change between models with 2 displays per group (value 002,
default setting) or 1 display per group (value 001).
TeE
Steam boiler's temperatura in stand-by mode
TiE
Inactivity time (in minutes) after which the temperatura of the steam boiler
is set to the stand-by one (TeE parameter). If this value is set to 0, stand-by
function is deactivated.
Pxy
Pre-infusion of the selection y (y = 1,2,3,4) of the x button, configurable
between 0 and 5 seconds. For example, P12 is the pre-infusion time (pump
ON) of selection 2 in group 1. Pump time OFF is always 3s. Selection 5
(XL, continuous delivery) does not have pre-infusion time.
Cr
Timer, activated or deactivated. When activated, brewing time is showed in
the display on the right of each coffee group during the brewing process.
Ux
Indicates the offset between the regulated temperature and that shown by
the group x display. This parameter allows to apply an offset between (-9.9,
+9.9) ºC.
AC
Steam boiler activated / deactivated
SP
Indicates the number of partial services (since the last reset to 0) of the
group from which we are viewing the data.
STG
Indicates the number of total services of the machine since the last reset
to 0.
ST
Indicates the total number of services (historical without considering resets)
of the machine.