ATTENTION!
It is possible to activate the machine so that only the keypads and screens are
illuminated, disconnecting the resistors and alarms. To connect the machine in
this way, with the machine off, press keys 1 and 4 of group 1, and keep them
pressed while activating the main switch, until the keypads and screens are
illuminated. To deactivate, we must repeat the same operation.
14 - Specific functions of model ZERO
The Barista T ZERO model performs the following options which need to be set through
the main keyboard of the machine:
a. Control of the temperature of the coffee groups, with 8 selections available for each
group.
b. Activation of the demonstration mode, through which we deactivate the resistances
and alarms.
c. Maximum power control by selecting the maximum number of heating elements
resistors that can work simultaneously (see power limitation table in section 5 -
electrical connection).
d. Activation of the pre-infusion.
e. Activation or deactivation of the steam boiler.
a.
Configuration of the group temperature (default setting 93ºC)
•
Get into the setting mode (press key 5 + 3) in group 1.
•
Key 5 is FLASHING in all control panels. It is important that this happens in all
groups, so we can modify each temperature accordingly.
•
Temperature may be showed as follows:
MAN.31 V13 MANUAL BARISTA T 2023_EN_ES_DE_FR.indd 23
MAN.31 V13 MANUAL BARISTA T 2023_EN_ES_DE_FR.indd 23
Key 1
Key 2
90ºC
OFF
OFF
91ºC
OFF
OFF
92ºC
OFF
ON
93ºC
OFF
ON
94ºC
ON
OFF
95ºC
ON
OFF
96ºC
ON
ON
97ºC
ON
ON
Key 3
OFF
ON
OFF
ON
OFF
ON
OFF
ON
23
18/10/2023 11:23:27