RS-232C specifications
Send
Receive data returned
Description of operation
Data sent from PC
озо
|
Command
which controls playback]
which
controls
playback).
|...
о]
EEE
speed in the positive (—) direction.
[STX] OSU [ETX]
[STX] OSU [ETX]
UP)
—9, -7, —5, —1, —1/5, -1/10, –1/30, SLOW PAUSE, «1/30, «1/10, +1/5, +1, +5, +7, +9
OSD command
Each time the OSU command is sent, the speed is changed in the positive (—) direction by one
setting.
Leave an interval of at least 150ms before sending this command for the second and
subsequent times.
When the maximum positive speed («9x normal speed) is reached, the
speed cannot be changed any further.
Ш INSERT COMMAND
ta
returned
Send
Description of operation
Data sent from PC
Recelve data
retur
| command
|
|
_ fomVTR
—
VTR
EN
—
| Insert pre-processing command.
| Insert pre-processing command.
If this |
77]
ENSEM
(INSERT)
command is sent when the cassette's
[STX] EIN [ETX]
[STX] EIN [ETX]
tab has been broken out, the tape mark
flashes and a warning tone is emitted.
Audio
dubbin
re-processin
command.
|f he ӨЛ Аа
is ж.
[STX] EAD [ETX]
[STX] EAD [ETX]
when
the cassette's
tab has
been
broken out, the tape mark flashes and
a warning tone is emitted
Command which executes insert up to
[STX] EIT: 000
the specified position.
When
the
a
[ETX]
[STX] EIT [ETX]
position specified by data is reached,
i
i o n
i
Counter data
the insert operation is ended, and play | ==="
pause mode is entered.
Fl
oL
UD
DM
Sign Hour
Minutes
Seconds
Frame
|
—:- sign
+: blank
Example:
Insert up to 1 hour 12 min. 35 sec. 00 frame
[STX] EIT : _ 1123500 [ETX]
t
A blank must be input here.
Note: The counter
must
be reset before sending the EIT
command.
Command
which
executes
audio
[STX] EAT : DOC
i
dubbing up to the specified position.
0000
[ETX]
[STX] EAT [ЕТА]
When
the position specified by the
data is reached, the audio dubbing is Counter data
;
[l
LD)
ГГ]
DO
DD
знай ач
pray: paso
MOUE:
de
Sign Hour
Minutes Seconds
Frame
—:- sign
+: blank
Example:
Audio insert up to 1 hour 12 min. 35 sec. 00 frame
[STX] EAT : _ 1123500 [ETX]
t
A blank must be input here.
Note: The counter must be reset before sending the
EAT command.
Note:
When the insert operation is activated using the EIN command, it will be cut off at the "0:00.00" counter setting.