12
Decommissioning
12.1
Switching off the pump and tem-
porary shutdown
12.2
Shutdown and storage
13
Maintenance/repair
Installation and operating instructions • Wilo-CronoLine-IL-E, Wilo-CronoTwin-DL-E, Wilo-CronoBloc-BL-E • Ed.01/2024-02
CAUTION
Risk of property damage due to overheating!
Hot fluids can damage the pump seals when the pump is at a standstill.
After deactivating the heat source:
• Allow the pump to run until the fluid temperature has dropped to an
appropriate level.
CAUTION
Risk of property damage due to frost!
If there is a danger of frost:
• Drain the pump completely to avoid damage.
•
Close the shut-off device in the pressure pipe. If a non-return valve is installed in the
pressure pipe, and there is counter pressure, the shut-off device can remain open.
•
Do not close the shut-off device in the suction line.
•
Switch off the pump and allow it to drain completely. Ensure the coasting is smooth.
•
If there is no danger of frost, make sure the fluid level is sufficient.
•
Operate the pump every month for 5 minutes. Doing this prevents deposits from occur-
ring in the pump compartment.
WARNING
Risk of injury and damage to property!
• Dispose off the pump contents and rinsing fluid by taking the legal
regulations into account.
• Always wear protective clothing, safety gloves and safety glasses
when working.
•
Clean the pump thoroughly prior to storage!
•
Drain the pump completely and rinse thoroughly.
•
The remaining fluid and rinsing fluid should be drained, collected and disposed off via
the drain plug. Observe local regulations along with the notes under "Disposal"!
•
Seal suction and discharge connection with caps.
•
After removal, store the pump in a dry, dust-free location.
•
Maintenance work: The technician must be familiar with the use of operating fluids and
their disposal.
•
Electrical work: a qualified electrician must carry out the electrical work.
•
Installation/dismantling: The technician must be trained in the use of the necessary
tools and fixation materials.
It is recommended to have the pump serviced and checked by the Wilo customer service.
en
141