Télécharger Imprimer la page

Nice MhouseKit WS100WCK Instructions Et Avertissements Pour L'installation Et L'utilisation page 69

Publicité

Les langues disponibles

Les langues disponibles

1 fast green flash followed by
1 fast red flash + 1 second
pause
2 fast red flashes + pause for
1 second
Red LED
on
Red LED on
1 red coloured short flash
every 0.5 seconds
1 green coloured short flash
every 0.5 seconds
1 red+green coloured short
flash every 0.5 seconds
LED P2
Off *
On
Series of quick flashes, from
1 to 4
5 quick flashes
1 slow flash
3 slow flashes
5 slow flashes
LED P3
Off *
On
1 flash per second
2 flashes per second
LED P4
Off *
On 1 slow flash
2 slow flashes
BUZZER
Short beep + long beep at
the end of the manoeuvre
The automation is neither moving nor
in test. The control unit has at least
one accessory device installed; the last
manoeuvre was successful and all devices
respond correctly the control unit did
not receive a good radio signal from
one of them.
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was
successful and all devices respond correctly
but at least one device has a battery
which is nearly empty and at least one
device from which the control unit did
not receive a good radio signal.
The automation is neither moving nor
in test. The control unit has at least
one accessory device installed; the last
manoeuvre was successful and all devices
respond correctly but at least one device
on the network did not respond.
The automation is moving or in test. The
control unit has at least one pair of photo-
cells installed.
Network learning procedure by new (clon-
ing) in course; the control unit is waiting for
the address of the old network
The control unit is detecting the old devices
Network learning procedure by new (clon-
ing) in course; the control unit has received
the address of the old network
Status
All OK
Memorisation in Mode 1
Memorisation in Mode 2
Cancellation OK
Wrong command
Memorisation OK
Cancellation OK
Status
All OK
All OK
The device recognition phase has not been
carried out, or there are errors in the data
saved
Devices recognition phase in progress
Status
All OK
All OK
There is no memorised opening angle
Opening angles recognition phase in pro-
gress
Status
The automation has just completed a
manoeuvre or test phase
Limited radio communication; if possible, search for a better
position for the device
Check the battery charge level on the wireless devices; activate
the test procedure (paragraph 8.2 ).
Limited radio communication; if possible, search for a better posi-
tion for the device
Check the battery charge level on the wireless devices; activate
the test procedure (paragraph 8.2 ).
Limited radio communication; if possible, search for a better
position for the device
Normal operation if there is an obstacle between at least one pair
of photocells, or at least one photocell is not responding. Check
the battery charge level on the wireless devices; activate the test
procedure (paragraph 8.2 ). It is possible that radio communica-
tion is at its limit; if possible, search for a better position for the
device. There may also be a radio interference problem.
Normal operation
Normal operation
Normal operation
Action
No memorisation in progress.
During memorisation in mode 1, it is normal for it to take a maxi-
mum of 10 s.
During memorisation in mode 2, it is normal for it to take a maxi-
mum of 10 s.
Completion of deletion of a transmitter.
A command has been received from an unmemorised transmitter
Memorisation completed successfully
Completion of deletion of all transmitters.
Action
"Slow" speed selected
"Fast" speed selected
It is possible that there are faulty devices. Check and if necessary
repeat the device recognition phase (see paragraph 10.3.3 "Add-
ing further devices to an existing system").
Indicates that it is in the process of recognising the attached
devices (this will take a maximum of a few seconds).
Action
Cycle operation.
Complete cycle operation.
Carry out the recognition phase (see Chapter 3.5.2 - Leaf open
and closure angles recognition).
Indicates that the open angles self-learning phase is in progress.
Action
Check led P1