––– STEP 10 –––
10.1 - ADVANCED ADJUSTMENTS
10.1.1 - Parameter adjustment using radio transmitter
Using the radio transmitter you can adjust certain operating parameters
on the control unit: there are eight parameters (Table 9):
1) Pause time: duration for which the leaves remain open (in the case of
automatic closure).
2) Pedestrian opening: pedestrian opening mode of the leaves.
3) Motor force: maximum force above which the control unit detects an
obstacle, and reverses the movement.
4) "OPEN" function: sequence of movements associated to each "OPEN"
command.
5) Open input configuration on control unit: allows you to program the
Open input functionality, as described in Table 4.
Parameters
N°
Value
1
10s
2
20s (*)
Pause time
3
40s
4
80s
1
Open 1 leaf halfway
2
Fully open 1 leaf (*)
Pedestrian opening
3
2 leaves partially opened to 1/4 of the full course
4
2 leaves partially opened to half of the full course
1
Low
2
Medium low (*)
Motor force
3
Medium high
4
High
1
"Open", "Stop", "Close", "Stop"
2
"Open", "Stop", "Close", "Open" (*)
"OPEN" function
3
"Open", "Close", "Open", "Close"
4
Open only
(*)
Original factory value
Parameters
Open input configuration on the control unit
Motor 1 and Motor 2 discharge in closure
Motor 1 and Motor 2 discharge in opening
(*)
Original factory value
FURTHER DETAILS
6) Discharging Motor 1 and Motor 2 when closing: adjusts the length of
the "brief reverse" of the motors after execution of the closing manoeu-
vre, in order to reduce the final residual force.
7) Discharging motor 2 when opening: adjusts the length of the "brief
reverse" of the motor after execution of the opening manoeuvre, in
order to reduce the final residual force.
TABLE 9
Action: operation to be carried out at step 3 in the
recognition phase
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
TABLE 10
N° Value
1
Open (*)
2
pedestrian opening
1
No discharge (*)
2
0.1s (Minimum)
3
0.2s
4
0.3s
5
0.4s (Medium)
6
0.5s
7
0.6s
8
0.7s (Maximum)
1
No discharge (*)
2
0.1s (Minimum)
3
0.2s
4
0.3s
5
0.4s (Medium)
6
0.5s
7
0.6s
8
0.7s (Maximum)
Action to perform
Press T1 once
Press T1 twice
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T3 five times
Press T3 six times
Press T3 seven times
Press T3 eight times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T4 five times
Press T4 six times
Press T4 seven times
Press T4 eight times
English – 19