34
2
1
7.3 - GATE LEAF OPEN AND CLOSURE ANGLES RECOG-
NITION
After self-learning the devices, the control unit must recognise the leaf
opening and closing angles. In this phase the opening angle of the leaves
from the mechanical end closing stop up to the mechanical opening stop
is detected. The presence of fixed and sufficiently robust mechanical
stops is essential.
01. Carry out motors release using the appropriate keys (see paragraph
11.3 - Usage guide) and move the leaves to mid-course, in such a
way that they are free to move in the opening and closing directions;
then release the motors.
02. On the control unit press and hold P4 (fig. 31) for at least 3 seconds,
then release it; wait for the control unit to perform the recognition:
closure of motor M1 up to the mechanical stop, closure of motor M2
up to the mechanical stop, opening of the motor M2 and the motor
M1 up to the mechanical opening stop; full closure of M1 and M2.
- If the first manoeuvre of one or both wings is not a closure, press
P4 to stop the recognition phase and then invert the polarity of the
opening motor(s) by swapping over the two brown and blue wires on
the terminal.
- If the first motor to carry out a closing move is not M1, press P4 to
stop the recognition phase and then swap the motors connections
on the terminals.
- If during the recognition phase a device actuates (photocells, key
selector switch, P4 pressed, etc.) the recognition phase will be
stopped immediately. It will then be necessary to repeat it in full.
03. If the P4 LED (fig. 31) flashes at the conclusion of the recognition
process, it means that an error has occurred; see section 10.5 "Trou-
bleshooting".
The recognition stage of the opening angles can be repeated again at any
time, even after the installation (for example, if one of the opening stops is
moved); it is sufficient to repeat the procedure starting from step 1.
16 – English
1
3
7.4 - RADIO TRANSMITTERS CHECK
2
To check the transmitters, you just need to press on one of its 4 keys,
check that the LED flashes and that the automation carries out the com-
mand sent.
The command associated to each key depends on the way in which they
were stored (see paragraph 10.4 "Memorisation of radio transmitters").
The transmitters supplied are already memorised, and pressing their keys
transmits the following commands (fig. 35):
Key T1 = "OPEN" command
Key T2 = "Pedestrian Opening" command
Key T3 = "Open Only" command
Key T4 = "Close Only" command
35
4
T1
T3
7.5 - ADJUSTMENTS
7.5.1 - Leaf speed selection
Leaf opening and closing can be done in two speeds: "slow" or "fast".
To move between one speed and the other, quickly press P3 (fig. 31); the
corresponding P3 LED (fig. 31) lights up or goes out; when the LED is off
the speed is "slow", when the LED is lit the speed is "fast".
7.5.2 - Selecting the operating cycle type
The closing and opening of the gate can be performed according to two
different operating cycles:
• single cycle (semiautomatic): with one command the gate opens, and
will remain open until the next command causing it to close.
• Complete cycle (automatic closure): with one command, the gate opens
and recloses automatically after a short space of time (for the duration
see paragraph 10.1 "Parameter adjustment using radio transmitter").
To move between one operating cycle and the other, quickly press P4
(fig. 31); the corresponding LED P4 (fig. 31) lights up or goes out; when
the LED is off the cycle is "single", when the LED is lit the cycle is "com-
plete".
T2
T4