Default
Parameter
Value
Broken Pipe
Disabled
Mode
Broken Pipe
10 M
Delay
Broken Pipe
25
Pressure
Minimum Off
3 s- Submersible
Time
10 s - Surface
Underload
Underload
Mode Select
Underload
59
Frequency
Underload
65
Level
Underload
Smart Reset
Off Time
3 s - Submers-
Underload
ible
Prime Time
120 s - Surface
Over Pressure
20
Offset
PT100 Enable
Disabled
PT100
100
Alarm Limit
PT100
125
Fault Limit
Units
Range
DIP
Switch
• Enabled
N/A
Yes
• Disabled
Minutes • 1 to 60
• 0 to
PSI
(0.95*Sensor
Range)
Seconds • 0 to 6000
• Disabled
N/A
• Underload
• (Low
Frequency
Limit) to
Hz
(High
Frequency
Limit)
%
• 25% to 95%
• Smart Reset
• 5 to 1440
Minutes
Minutes
Manually
Seconds • 0 to 3000
• 10 to ((Sensor
Range) -
GREATER OF
PSI
(Pressure
Setpoint 1 or
Pressure
Setpoint 2))
• Enabled
N/A
• Disabled
• 40 to (PT100
Celsius
Fault Limit)
• (PT100 Alarm
Celsius
Limit) to 150
Set Parameter via:
FE
Progra
Connect
mming
App
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
Yes
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
SPECIFICATIONS
Programming Defaults
Change
while
Description
Running
Enables or disables broken pipe pro-
No
tection
Sets the amount of time the drive
No
must run before broken pipe protec-
tion will stop the motor.
Sets the pressure that the system
No
must be below for broken pipe pro-
tection to stop the motor.
Set the minimum time the drive
No
must be off before running again.
Enables or disables Underload pro-
No
tection
Sets speed at which drive must run
No
for underload detection to trip.
Yes
Sets underload sensitivity
Sets time for drive to restart after
Underload condition.
Yes
Default is Smart reset which doubles
time if underload occurs within 180
seconds of running.
Sets the time before underload pro-
No
tection is active upon startup
Sets the pressure offset from pres-
sure setpoint to indicate system
Yes
overpressure. Ex. Setpoint of 50 and
over pressure offset of 20 will stop
system from going above 70 PSI.
Enables or disables the PT100 pro-
Yes
tection
Yes
Sets the alarm limit of the PT100
Yes
Set the fault limit of the PT100
51