SPECIFICATIONS
Common Specifications
Voltage
Phase In
Frequency
Current (max)
Input from
Power Source
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s) Refer to
Voltage
Phase Out
Output to
Frequency Range
Motor
Current (max)
Wire Gauge Size(s) Refer to
Factory Preset
Pressure
Setting
Transducer Range
Temperature
Operating
Relative Humidity
Conditions*
Environment
Temperature
Storage**
Shelf Life
* Operating temperature is specified at full output power when installed as recommended. Refer to
Temperature Foldback" on page
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
Applicable Standards
Agency Safety Listings:
•
UL 61800-5-1
•
CSA C22.2 No. 274
•
UL 50
•
UL 50E
Enclosure Ratings:
•
UL Type 3R
SubDrive Connect Plus
208/230 ± 10% VAC or 460 ± 10% VAC, depending on model
Single-Phase or Three-Phase (208/230 VAC) or Three-Phase (460 VAC), depending on model
60 Hz
"Input (Power) Wire and Fuse Sizing" on page 17
Model dependent, refer to
~ 0.75
230V Frame 2/Frame 3: 25W 460V Frame 2/Frame 3: 32W
"Input (Power) Wire and Fuse Sizing" on page 17
Model dependent, refer to
"Input (Power) Wire and Fuse Sizing" on page 17
208/230VAC or 460VAC depending on model
Three-Phase
30-60 Hz: Submersible Pump (Three-Phase)
15-60 Hz: Centrifugal Pump (Three-Phase)
Model-dependent, refer to
"Applications" on page 8
"Centrifugal Pump Motors" on page 18
0 PSI for Setpoint 1 and Setpoint 2
Transducer: 0 to 5PSI below Transducer maximum. The programmed drive Transducer range is
selectable from 100 to 300 PSI in 10 PSI increments.
–13 °F to 104 °F (–25 °C to 40 °C)
20-95%, non-condensing
Pollution Degree 2
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
29.
Common Specifications
.
.
"Over
SPECIFICATIONS
47