6.2 Electrical connections for the various peripherals - Fig.
21 à 30
Cut the electric power supply to the motor before performing any work on peripherals. If the
display remains off a er working on the system, check the wiring (for possible short circuits
or polarity reversals).
General electrical diagram (Fig. 21)
Photoelectric cells (Fig. 22)
Two types of connections can be made:
A : Standard (without self test): program the setting"P2" = 2.
B : With self test: program the setting "P2" = 1.
This
means
that
an
check photoelectric cell operation every time the door operates.
If the test fails, no door movement is possible.
Reflex photoelectric cell (Fig. 23)
With self test: program the setting "P2" = 1.
This means that an automatic test is conducted to check photoelectric cell operation every
time the door moves.
If the test fails, no door movement is possible.
Sensor bar (Fig. 24)
With self test: program the setting "P2" = 1.
This is used to perform an automatic test of sensor bar operation every time the door moves.
If the test result is negative, no door movement is possible.
Make sure you have correctly configured parameter "P2" taking into account
the photoelectric cells or the sensor bar.
Orange light (Fig. 25)
Program the setting "P1" depending on the required operating mode:
- Without warning before door movement: "P1" = 0.
- With a 2 s warning before door movement: "P1" = 1.
Code keypad (Fig. 26)
Pedestrian door safety kit (Fig. 27)
When the pedestrian door contact is fitted, it must be connected in place of the jumper normally
fitted between terminals 5 and 6.
If the pedestrian door contact is removed, the jumper between terminals 5 and 6.
Battery (Fig. 28)
Aerial (Fig. 29)
Remote lighting (Fig. 30)
Class 2 (double insulation) light units that are connected do not require an earth connection.
- 5 compact fluorescent or LED lamps or
- 2 power supplies for low-voltage LEDs or
- 1 halogen lamp, 500 W max
Siren
For more information on connecting the siren, consult the installation manual.
Programme the parameter "Pb" to activate the siren:
- Siren inactive "Pb" = 0.
- Siren active: "Pb" = 1 or "Pb" = 2.
7
automatic
test
is
conducted

7.1 Meanings of the various parameters

(Boldface text = default values)
Total operating mode
Values
0: sequential
1: sequential + timed close
2: automatic closure
3: automatic closure by cells
to
Comments
P0 = 0: Each press on the remote control causes the motor to move
(initial position: door closed) as per the following cycle: open, stop,
close, stop, open...
P0 = 1: Automatic closure mode operation is only possible if photoelectric
cells are fitted, i.e. P2=1 or P2=2.
In sequential mode with automatic timed close:
- the door is closed automatically a er the timed delay programmed in
parameter "t0",
- pressing a button on the remote control interrupts the movement taking
place and the timed close.
P0 = 2: Automatic closure mode operation is only possible if photoelectric
cells are fitted, i.e. P2=1 or P2=2.
In automatic closure mode:
- the door is closed automatically a er the timed delay programmed in
parameter "t0",
- pressing a button on the remote control during opening has no effect,
- pressing a button on the remote control during closing causes it to
reopen,
- pressing a button on the remote control during the timed close
restarts the timed delay.
P0 = 3: Automatic closure mode operation is only possible if photoelectric
cells are fitted, i.e. P2=1 or P2=2.
A er the door is opened, movement in front of the cells (safe closure) will
close the door a er a short timed delay (fixed at 5 seconds).
If there is no movement in front of the cells, the door will close automatically
a er the timed close programmed in parameter "t0".
If there is an obstacle in the cells' detection zone, the door will not close. It
will close once the obstacle is removed.
Orange warning light
Values
0: without advance warning
1: with 2 s advance warning
Comments
If the garage opens onto a public road, always select with advance
warning: P1=1
Safety input
Values
0: no safety mechanism
1: safety mechanism with self test
2: safety mechanism without self test
Comments
If value 0 is selected, the safety input is not taken into account.
If value 1 is selected, the system's self test is run at the start of every
operating cycle.
If value 2 is selected, the safety system runs without a self test: it is
essential to test its proper operation every six months.
Obstacle detection
sensitivity
Values
0: very low sensitivity
1: low sensitivity
2: standard
3: high sensitivity
If this parameter P3 is modified, the installer must check that the obstacle detection
complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to persons, e.g. when
trapped by a door.

7 SETUP

WARNING