Error And Failure Codes Displayed; Accessing Stored Data; Technical Specifications - SOMFY Dexxo Pro 800 RTS Manuel D'installation

Masquer les pouces Voir aussi pour Dexxo Pro 800 RTS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Dexxo Pro RTS

12.3 Error and failure codes displayed

Code
Description
Comments
Safety input
Displayed when the
always active
safety input remains
active for more than
three minutes.
Safety
The safety device
mechanism self
self test failed
test fault
Other faults
These codes
and failure
correspond to various
conditions
electronic circuit
board failures.
Detection of
Displayed when an
forced entry
action occurs from
outside the garage
(read by reinjection
of power)
Detection of
Displayed when an
forced entry
action occurs from
outside the garage
(read by optical
encoder)
Maintenance is
Displayed when
required
maintenance is
required on the
installation. The
number of cycles
programmed in
parameter "PA" has
been reached.

12.4 Accessing stored data

To access stored data, select the "Ud" setting then press "OK" as shown in Fig. 41.
Data
Description
Total cycle counter: tens and units
Total cycle counter: thousands and hundreds
Total cycle counter: hundreds of thousands
Cycle counter with obstacle detection: tens and units
Cycle counter with obstacle detection: thousands
Number of control channels memorised
Log of the last ten faults (d0 the most recent - d9 the oldest)
to
Clears the fault log: press "OK" for 7 s (Fig.41).
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
Action required?
Check that there is no obstacle
triggering cell or sensor bar
detection.
Check that "P2" is setup correctly
depending on the devices connected
to the safety input.
Check safety device wiring.
When photoelectric cells are used,
check their proper alignment.
Check that "P2" is setup correctly
depending on the devices connected
to the safety input.
Check safety device wiring.
When photoelectric cells are used,
check their proper alignment.
Cut the power supply (mains &
battery back-up), wait for a few
minutes then re-connect the power
supply.
Perform a learning cycle.
If the fault persists, contact Somfy
Technical Support.
Press a button on the memorised
remote control to stop the siren.
Start a complete opening and closing
cycle.
Press a button on the memorised
remote control to stop the siren.
Start a complete opening and closing
cycle.
Confirm or modify the current
"PA" value, or deactivate the
"Maintenance required indicator"
function.
13 TECHNICAL SPECIFICATIONS
BASIC TECHNICAL CHARACTERISTICS
Mains supply
Standby
Max. power
consumption
Operation
Peak force
Traction force
Starting force
(1)
Use
Max. speed
Programming interface
Operating temperature
Travel end limits
Electrical insulation
Built in lighting
Somfy radio frequency
Number of channels that can be memorised 32
CONNECTIONS
Type
Safety input
Compatibility
Pedestrian door safety input
Wired control input
Remote lighting output
Orange light output
24 V controlled power supply output
Safety input test output
Accessory power supply output
Remote aerial input
Backup battery input
Autonomy
Charge time
OPERATION
Forced operation mode
Independent lighting control
Lighting time delay (a er movement)
Automatic closing mode
Orange light pre-warning
While closing
Before opening
Safety input operation
(Dangerous
Movement Area
Accessible to the
Public)
Built-in obstacle detection
Operation when an obstacle is detected
Preset partial opening command
Progressive start up
Opening speed
EN
Dexxo Pro 800 RTS
Dexxo Pro 1000 RTS
230 V - 50 Hz
5 W
600  W(with 500 W remote lighting)
800 N
1000 N
650 N
800 N
Intensive use
18 cm/s
7 buttons - 2 character LCD display
- 20 ° C / + 60 ° C - indoor dry - IP 20
Mechanical stopper at opening
Memorized end limit position at closing
Class 2: double insulation
LED
433,42 MHz
< 10 mW
Dry contact: NC
Photoelectric TX/RX cells - Reflex cell - Sensor
strip with dry contact output
Dry contact: NC
Dry contact: NO
230 V - 500 W - class 2
5 compact fluorescent or LED lamps or
2 power supplies for low-voltage LEDs or
1 halogen lamp, 500 W max
24 V - 15 W with flashing management
integrated into the drive
Yes: for possible photoelectric TX/RX cell
self-test
Yes: for possible reflex cell or sensor strip
self-test
24 V - 500 mA max
Yes: RTS aerial compatible (Réf. 2400472)
Yes: battery pack compatible (Réf. 9001001)
24 hours; 5 to 10 cycles depending on door
48 hours
Pressing the motor control button
Yes for remote lighting
Programmable : 0 s to 600 s
Yes: programmable closing time delay from
0 to 120 s
Programmable: with or without prior
warning (duration set to 2 s)
Programmable: Stop - Partial
reopening - Full reopening
Programmable: no effect or motion refused
Adjustable sensitivity: 4 levels
Programmable : partial re-opening or full
reopening
Yes can be selected: adjustable partial
opening position
Yes
Programmable from 3.5 cm/s to 18 cm/s:
10 possible values
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dexxo pro 1000 rts

Table des Matières