SOMFY Dexxo Pro 800 RTS Manuel D'installation page 31

Masquer les pouces Voir aussi pour Dexxo Pro 800 RTS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Dexxo Pro RTS
Partial operating mode
Values
0: sequential
1: sequential + timed close
Comments
P4 = 0 : Each press on the remote control causes the motor to move
(initial position: door closed) as per the following cycle: open, stop,
close, stop, open...
P4 = 1: Automatic closure mode operation is only possible if photoelectric
cells are fitted, i.e. P2=1 or P2=2.
In sequential mode with automatic timed close:
- the door is closed automatically a er the timed delay programmed in
parameter "t2",
- pressing a button on the remote control interrupts the movement
taking place and the timed close.
Closing speed
Values
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
By default, 6: approx. 12 cm/s
Comments
If spurious detection of obstacles occurs when this parameter is
modified, end limit setting and auto-programming will have to be carried
out again.
If this parameter P5 is modified, the installer must check that the obstacle detection
complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to persons, e.g. when
trapped by a door.
Partially open position
Values
Storing the position as illustrated in Fig. 32.
Docking zone when closing (reduction of speed)
Values
0: short (over approx. the last 5 centimetres)
1: standard (over approx. the last 30 centimetres)
2: long (over approx. the last 50 centimetres)
If this parameter P7 is modified, the installer must check that the obstacle detection
complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to persons, e.g. when
trapped by a door.
Opening speed
Values
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
Choice of operating direction (type of door)
Values
0: direction 1: all types of doors except swinging doors
1: direction 2: swinging doors
Comments
If this setting requires modification the end limit setting must be
repeated along with self-learning.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
WARNING
WARNING
Maintenance required indicator
Values
0: no indication
1: 100 cycles
to
99 : 9900 cycles (number of cycles = value x 100 cycles)
Comments
Once the motor reaches the programmed number of cycles, the
integrated light flashes each time the door moves to signal that
maintenance is required.
To stop the integrated light flashing, either the current value must be
confirmed or modified, or the maintenance indicator must be deactivated.
Detection of forced entry
Values
0: no detection of forced entry
1: obvious forced entry detected
2: less obvious forced entry detected
Comments
Detection of forced entry starts operating 30 seconds a er the door is
closed.
If forced entry is detected, the siren sounds for 2 minutes. To stop it,
press one of the buttons on the remote control.
If photoelectric cells are installed (P2=2), these must be connected to
the permanent power supply (refer to the installation manual for the
siren).
Safety action prior to opening (safety ADMAP)
Values
0: no effect
1: movement rejected
Comments
If value 1 is selected, triggering the safety input will inhibit door opening.
Safety action during closure
Values
1: stop
2: stop + partial re-opening
3: fully reopen
Comments
Value 1 is not allowed when using a sensor bar on the safety input.
Obstacle detection action during closure
Values
2: stop + partial re-opening
3: fully reopen
Total operating mode automatic timed close
Values
0 to 12 (time delay value = value x 10 s)
2:20 s
Lighting time delay
Values
0 to 60 (time delay value = value x 10 s)
6:60 s
Partial operating mode automatic timed close
Values
0 to 12 (time delay value = value x 10 s)
2:20 s
Programming example:
setting the "
(Fig. 31)
Setting up a long soft stop function zone"P7" = 2.
EN
P7
" closure approach speed
8