Testing the Safety Devices

The lifting device is equipped with following safety equipment:
pressure gauge (with red danger zone display)
alarm signal (audio)
Check this equipment
at the beginning of each shift (when operating in shifts),
once a week (when operating continually).
Correct faults before operating the device. If faults occur during operation, switch the device off
and correct the faults before continuing work with the device.
3.8.1

Inspecting the vacuum hoses and hose clamps

Check that all vacuum hoses and hose clamps are securely seated. Tighten any loose connections.
3.8.2

Testing the vacuum reservoir

See the sub-section "Leak test" in the section "Maintenance"
Rectify any detected faults before using the lifting device. If a fault becomes apparent during,
switch off the lifting device and rectify the fault.
3.9

Damages of suction plate

Avoidance of damages:
To avoid damages of the rubber seal on the suction plate (chinks, abrasion) take notice, that:
during the operation (lifting, transporting and lowering) with the device, the suction plate does not brush or pump
against other products or materials.
Otherwise the rubber seal on the suction plate could be damaged (danger of pressure loss).
Load could fall down. Danger of accidents!
3.10

Protective equipment

The protective equipment must consist, according to the safety regulations of
the following parts:
11 / 32
Safety
V7
Protective clothing
Safety gloves
Safety shoes
Hearing protector