Operating Manual - Vacuum Pump TFK 12
Vane service
Disconnect the pump from the power supply.
-
Mark the position of the cover to the housing and loosen the 4 M8 nuts on the pump head.
-
Lift and remove the pump cover.
-
Remove the vanes and measure the vane length (see diagram above). If the length is below 18mm
-
replace them with new vanes.
Replace all 6 vanes together.
-
Order number of a set (6 pieces) of vanes: 22.09.01.00147
-
Check all parts for damage. If any damage is discovered return the pump for repair to the
manufacturer.
Whilst the pump is open rotate the shaft by hand. Check for smooth operation to determine if any
-
parts rub or bearings are damaged.
Replace the cover and fasten with the 4 x M8 nuts. Use a torque of 20 Nm.
-
Clean or replace all filters.
-