Suction Pads/ Seals; Vacuum Filter; Warning Device (Audible); Leak Test - probst SH-2500-UNI-B Instructions D'emploi

Système de préhension par aspiration
Masquer les pouces Voir aussi pour SH-2500-UNI-B:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
SH 2500-UNI-B
10.5

Suction pads/ seals

Remove items and contaminations such as adhesives, glue, saw dust, dust etc. from the seals at least once a week.
Use glycerin to clean the seals.
Immediately replace damaged seals (those with tears, holes, ripples).
Do not use petrol (gasoline) to clean the device. It is highly flammable and its fumes are hazardous. Use cold-
cleaning solvent. Do not smoke while cleaning.
Do not use aggressive or corrosive fluids to clean the device. The vacuum hose will otherwise become leaky or be
destroyed.
10.6

Vacuum filter

Check the filter at least once a week, blow the filter cartridge out (from the inside to the outside).
Do not knock the filter!
When it is contaminated heavily, replace the filter cartridge.
Do not allow dust to enter into the suction opening when removing the filter cartridge.
10.7

Warning device (audible)

See the warning device operating instructions (appendix)

10.8 Leak test

Switch on the lifting device/engine.
Place the lifting device on a piece of sheet metal or a similar surface and apply suction.
Caution: Only apply suction to the sheet; do not lift it! It can loosen while being checked and fall off.
Switch the pump on and wait until a vacuum pressure of -0.6 bar is reached.
Switch off the engine and watch the pressure gauge. Suction should not decrease by more than 0.1 bar within 5
minutes. If it does, locate the cause for this error and correct it before operating the device.
Pos: 27 /07 Wart ung und Pflege /04 Prüf ungspflicht/ Ü_Pr üfungspflicht @ 0\mod119_2. doc @ 7095 @
30 / 32
Maintenance and care
V7
GB

Publicité

Table des Matières
loading

Table des Matières