P.co - setp
Type of setpoint (internal/external)
P.co - inp
Analogue input type
Enter the analogue input signal type according to the transmitter signal.
P.co - filt
Filtering of the process actual values. Valid for all process actual value types.
Range: 0..9
Works setting: 0
Setting in 10 steps
Setting
Limiting frequency [Hz]
0
1
2
3
4
5
6
7
8
9
134
Setting in 10 steps: 0..9
Effect
10
minimum filter effect
5
3
2
1
0,7
0,5
0,3
0,2
0,1
maximum filter effect
Internal setpoint by keys on the TopControl
External setpoint by analogue input
Analogue input 4...20 mA
(Flow; Pressure; Level; Analytical)
Analogue input Frequency (Flow)
Analogue input Pt100
(Temperature)