Electric wire rope winch BETA 2.1 EL
English
6.2 Explanation to drive groups FEM 9.511 for rope drives
The electric wire rope winches are classified according to different drive groups, DIN 15020, FEM
9.511, ISO4301/1 (see tech. data, page 4)
Those drive groups refer to the rope drive and all mechanical parts of the winch.
It determines the period of time of safe operation depending on load collective.
running
time /
medium running time per day in
category
hour, related to one year
no.
Term
1
light
2
medium
3
heavy
4
very
heavy
6.3 Calculated operating times acc. to FEM 9.755
DIN 15020/1 FEM 9.511
ISO 4308/1; SO 4301/1
Load collective
line
factor of the load spectrum
light 1 - L1
k = 0,5
1
(km 1 = 0,125 = 0,5 3 )
medium 2 - L2
0,5 < k < 0,63
2
(km 1 = 0,25 = 0,63 3 )
heavy 3 - L3
3
0,63 < k < 0,8
(km 1 = 0,5 = 0,8 3 )
very heavy 4- L4
0,8 < k < 1,0
4
(km 1 = 1 = 1,0 3 )
*)
not included in FEM 9.511
Apart from drive groups, the rope has to be checked and serviced regularly according to DIN15020, if
necessary, replace.
By comparing those data with the actual operating conditions and times the consumed part of the calcu-
lated operating time can be determined
The consumed part of the calculated operation has to be recorded by the operator (e.g. writing, count-
ing, measuring)
After expire of the calculated working life the winch has to be given a thorough examination
only by manufacturer or competent personnel authorised by manufacturer
1)
technische Änderungen vorbehalten
Symbol
Explanation
exceptionally maximum
load, continuously very
small loads
k < 0,50
often maximum load, but
continuously small loads
0,50 < k < 0,63
frequent maximum load,
continuously average
loads
0,63 < k < 0,80
continuously maximum
load and adjacent loads
0,80 < k < 1,00
1Dm
Drive group
1Em*
M1
(400) *
800
(200) *
400
(100) *
200
(50) *
100
design changes under reserve
04.01.601
V
V
V
V
006
012
025
05
≤ 0,12 ≤ 0,25 ≤ 0,5
≤ 1
Drive group
acc. to FEM9.511, DIN15020, ISO4301
1Em* 1Em* 1Dm 1Cm 1Bm 1Am
1Em* 1Dm 1Cm 1Bm 1Am
1Dm 1Cm 1Bm 1Am
1Cm 1Bm 1Am
2m
1Cm
1Bm
1Am
M2
M3
M4
calculated operation time D (h)
1600 3200 6300 12500 25000 50000
800
1600 3200
400
800
1600
200
400
800
changements techniques sous réserve
V
V
V
V
1
2
3
≤ 2
≤ 4
≤ 8
≤ 16
2m
3m
2m
3m
4m
2m
3m
4m
5m
3m
4m
5m
2m
3m
4m
M5
M6
M7
6300
12500 25000
3200
6300
12500
1600
3200
6300
1)
35
V
4
5
≥ 16
4m
5m
5m
M8
100000
50000
25000
12500