Télécharger Imprimer la page

Nice AVIO500 Instructions Et Avertissements Pour L'installation Et L'utilisation page 49

Motorisation pour portes de garage

Publicité

Les langues disponibles

Les langues disponibles

10.2 – SELECTION OF THE TYPE OF DEVICES CON-
NECTED TO "S1 EDGE"
Default = "S1 Edge" set for devices with normally closed
contact (terminal 9)
This procedure allows for setting the "S1 Edge" output for manag-
ing 8.2kOhm resistive edges.
The control unit constantly verifies the integrity of the edge by
ACTION
01.
PRESS START BUTTON FOR 3 SECONDS
PRESS THE RADIO BUTTON FOR 1 SECOND and then choose one of the
following:
02.
• S1 Edge = resistive edge > 03.a
• S1 Edge = device with normally closed contact (NC) > 03.b
S1 Edge = resistive edge: the yellow "set" light is ON.
03.a
If the setting is correct, proceed to item 05; otherwise, go to 04.a
Device with normally closed contact (NC):
04.a
PRESS THE START BUTTON FOR 1 SECOND
OR
S1 Edge = device with normally closed contact (NC): the yellow LED
03.b
"set" light is OFF.
If the setting is correct, proceed to item 05; otherwise, go to 04.b
Stop the programming sequences:
04.b
PRESS BOTH THE START AND RADIO BUTTONS FOR 2 SECONDS
PRESS THE SET AND RADIO BUTTONS
05.
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE PROCEDURE
10.3 – OTHER FUNCTIONS
To interrupt the following programming sequences at
any time, press the SET and RADIO buttons simultaneously
or wait 10 seconds.
ACTION
01.
PRESS START BUTTON FOR 3 SECONDS
PRESS THE SET BUTTON FOR 1 SECOND AND THEN SELECT ONE OF
THE FOLLOWING:
02.
• control unit block activated > 03.a
• control unit block deactivated > 03.b
Control unit block activated: yellow "set" LED light, red "radio" LED light
03.a
and red "error" LED light are ON.
If the setting is correct, proceed to item 05; otherwise, go to 04.a
Unlocking programming sequences:
04.a
PRESS BOTH THE START AND RADIO BUTTONS FOR 2 SECONDS
OR
Control unit block activated: yellow "set" LED light, red "radio" LED light
03.b
and red "error" LED light are OFF.
If the setting is correct, proceed to item 05; otherwise, go to 04.b
Stop the programming sequences:
04.b
PRESS BOTH THE START AND RADIO BUTTONS FOR 2 SECONDS
PRESS BOTH BUTTONS SET AND RADIO
05.
SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE
PROCEDURE
measuring the resistance between the two dedicated terminals.
In order to carry out the check on the safety devices,
the connected edges must be of the resistive type with 8.2
kOhm.
RESULT
All the LEDs turn off (if not, consult
Paragraph 10.3.1)
The red "error" LED turns on in the fixed
mode
The red "error" LED remains lit in the fixed
mode and the yellow "Set" LED turns off
The red "error" LED turns on in the fixed
mode
The red "error" LED remains lit in the fixed
mode and the yellow "Set" LED turns on
The LEDs return to the normal operation
configuration
10.3.1 – ACTIVATING/DEACTIVATING THE CONTROL
UNIT PROTECTION DEVICE
Default = control unit protection device not active.
This programming sequence allows for locking all control unit
programming sequences and the settings adjustable through the
dip-switches. To perform a new programming sequence or make
a dip-switch/trimmer modification effective, the protection must
be deactivated.
RESULT
All the LEDs turn off
The yellow led "set", the red led "radio" and
red led "start" go OFF
The yellow led "set", the red led "radio" and
red led "start" go ON
All the LEDs go back to standard behavior
English – 23

Publicité