3.5 – DESCRIPTION OF THE ELECTRICLA CONNECTIONS
The following is a brief description of the electrical connections (table
5 - fig. 31); for further information, please read section 9 ("Devices
connectable to the control unit").
TIMER FUNCTION: if START contact is kept closed (for
instance through a timer-controlled or bistable relay), con-
trol unit opens the door and leaves the door opened. The
automation does not accept closing commands (neither
automatic nor wired) until START contact is reopened.
In this mode, dip switch 1 STEP is set to OFF and dip 2
AUTO to ON to ensure that the gate never remains locked
open.
If START contact is kept closed during the control unit
starting after a blackout, the door will immediately execute
the start command.
31
14 – English
FL200
TX
12
11
10
Terminals Function
1 - 2
OUT1
3
Phototest
4
S2 Photo
5
0 V
6
Stop
7
Start
8
24 V
9
S1 Edge
10
24 V
11 - 12
Flashing
13 - 14
Aerial
RX
PHOTOTEST
OUT1
9
8
7
6
5
4
3
2
1
Table 5
Description
Command output by the
transmitter button. Volt-free relay
contact for 24V
max 3W
loads.
24V output for safety test. This
connection can be used instead
of the 24V
to connect
the power supply of the TX
photocell or the resistive S1
edge
Input for safety devices,
normally closed contact.
Function associated to dip
switch Func
Negative terminal for
accessories devices connected
Stop, normally closed contact
Start, normally open contact
Power supply 24V
Input for safety edges, normally
closed contact. Brief movement
inversion in case of obstacle
during closing and block of the
movement during opening.
Power supply 24V
24V
max. 15W flashing:
a FL200 flashing light can be
connected to this output
Antenna ground (13)
Antenna signal (14)