3.3 – ELECTRICAL CONNECTIONS
01. Open the cover by loosening the screw (fig. 25) and pushing
the button (fig. 26).
25
26
02. Remove the small disc [S] with a screwdriver (fig. 27).
27
S
3.4 – CONNECTING AVIO500 TO THE MAINS
CAUTION!
- Never cut or remove the cable supplied with AVIO500.
- If not already available, a power socket for connecting
AVIO500 to the mains must be made by qualified and expe-
rienced personnel in strict observance of current legislation,
standards and regulations.
AVIO500 must be connected to the supply mains by a quali-
fied electrician.
To test AVIO500, just insert the plug into a power outlet, using an
extension cord if necessary (fig. 30).
03. Feed the cables through the hole [S] (fig. 28).
S
28
04. Refer to fig. 29 and the connection descriptions in table 5
(par. 3.5) when making the connections:
- if using the flashing light aerial, remove the wire clip (connected
to terminal 14 as standard) and connect the RG58 shielded cable.
05. Once you have connected up all the cables, secure them us-
ing cable clips.
06. To close the cover (only if the control unit is already pro-
grammed - Step 4), rotate the cover and push it until you hear a
"click". Then tighten the screw.
29
30
English – 13