Télécharger Imprimer la page

Nice AVIO500 Instructions Et Avertissements Pour L'installation Et L'utilisation page 41

Motorisation pour portes de garage

Publicité

Les langues disponibles

Les langues disponibles

STEP 4
4.1 – DIP-SWITCHES ADJUSTMENT
DIP
SWITCHES
DIP
DIP-SWITCH
status
DIP 1 STEP
1-ON
2-OFF Step-by-step command
DIP 2 AUTO
1-ON
2-ON
1-OFF
2-ON
1-OFF
2-OFF Open / Close / Open com-
DIP 3
ON
CHECK
OFF
DIP 4
OFF
FUNCTION
ON
DIP1 "STEP":
If the dip-switch is put to ON, the step-by-step operating mode is
activated. At every start pulse (wired or via transmitter), the control
unit performs an action. Starts the motor if the automation system
is stopped, and stops it if it is moving. If the "STEP" dip-switch
is put to OFF, the OPEN FULLY/PAUSE/CLOSE FULLY/STOP
operating mode is activated (apartment block). The control unit
only accepts commands (either wired or via transmitter) for the
opening phase. Starts again from zero with the set delay when the
automation sys- tem is open. With the automation in the opening
phase, it continues to open, and with the system in the closing
phase it reopens fully. The automation can re-close with the time
set through the "PAUSE" knob, if the "AUTO" dip-switch is set to
ON. If not, it is necessary to give a START command (either wired
or via transmitter) with the automation fully open.
DIP2 "AUTO":
If the dip-switch is put to ON, the automatic re-closing function
is ac- tivated. The control unit automatically closes the leaves
after the time set through the "PAUSE" knob (see Paragraph
CONTROL UNIT SETTING
COURTESY
SELETTORE
LIGHT
LUCE DI
SELECTOR
CORTESIA
Description of
operation
mode: Open / Stop / Close
/ Stop
Step-by-step with automatic
closing (time set with the
"Pause" knob)
Opening only command
mode with automatic clos-
ing (condominium function)
mand mode (no Stop)
Test of the safety devices
connected at terminal [3]
"Phototest" enabled
Test of the safety devices
connected at terminal [3]
"Phototest" disabled
Devices connected to "S2
Photo" terminal [4] intervene
just during closing phase
with immediate inversion
Devices connected to "S2
Photo" terminal [4] intervene
by stopping the movement
both in opening and closing
phases
4.2). If the "AUTO" dip-switch is put to OFF, the automatic re-
closing function is deac- tivated. To close the leaves, therefore, a
command must be given (either wired or via transmitter).
DIP3 "CHECK":
If the dip-switch is put to ON, the safety devices connected to
terminal "Phototest" [3] are subject to a preventive check before
starting any movement. It's necessary to connect the positive
terminal of photocell's transmitter (or the normally closed contact
of a safety edge) to terminal n.3 in order to use this function.
If the "CHECK" dip-switch is put to OFF, the safety devices
connected to terminal "Phototest" [3] are constantly supplied.
DIP4 "FUNCTION":
If the dip-switch is put to OFF, the safety devices connected to
"S2 Photo" terminal [4] intervene just during closing phase with
immediate inversion. If the dip-switch is put to ON, the safety
devices connected to "S2 Photo" terminal [4] intervene by
stopping the movement both in opening and closing phases.
COURTESY LIGHT SELECTOR: it enables or disables the LED
courtesy light of the control unit.
4.2 – KNOB ADJUSTMENT
PAUSE
OBSTACLE
FORCE
KNOB
Description of operation
FORCE
Power: adjustment of motor power. Turning
the knob clockwise increases the motor's
power and speed. To validate the modification,
it is necessary to programme the gate path.
OBSTACLE
Obstacle, sensitivity to obstacles: adjustment
of the obstacle detection function. Turning the
knob clockwise increases the drive time before
obstacle detection (less sensitivity). Therefore, in
systems with particularly unfavorable mechani-
cal conditions, it is advisable to keep the drive
time high. OBSTACLE is set at half position (50%)
as factory setup.
PAUSE
Pause time before automatic gate closing.
Turning the knob clockwise increases the
pause time from 0 to 180 seconds. Please
note: this knob is functional only when AUTO
dip-switch is put to ON.
Varying the "POWER" knob has no effect until the
stroke is reprogrammed (STEP 6).
English – 15