Télécharger Imprimer la page

Nice AVIO500 Instructions Et Avertissements Pour L'installation Et L'utilisation page 46

Motorisation pour portes de garage

Publicité

Les langues disponibles

Les langues disponibles

STEP 9
Reset procedure deletes door travel parameters (step 6) and
all advanced functions (step 12). It can be performed in case of
programming mistakes and it brings the AVIO500 control board
to factory settings.
ACTION
01.
PRESS THE START BUTTON FOR 8 SECOND
02.
RELEASE START BUTTON
03.
PRESS THE START BUTTON FOR 3 SECOND
04.
RESET IS NOW COMPLETED
A NEW PROGRAMMING OF THE AUTOMATION'S
05.
MOVEMENTS IS REQUIRED
STEP 10
37
9.3
9.7
9.5
9.6
9.4
The control unit is prearranged for interfacing with different devic-
es dedicated to system control, system safety and other addition-
al functions. Below is a list of their connections and corresponding
functions.
10.1 – TRANSFORMER
Standard transformer of the system (supplied and connected) is
230V
*(primary) to 0-24V
10.2 – MOTOR
The maximum connectable load is 100W (max 3A) per motor.
20 – English
RESET PROCEDURE
DEVICES CONNECTABLE TO THE CONTROL UNIT
9.8
9.8
9.2
9.1
9.2
(secondary) to the control unit.
This reset doesn't affect memorized radio transmitters (see
step 5 for radio trasmitters management).
RESULT
All LED flash
All LED continue to flash
All LED light up in series
The red "ERROR" LED lights flashes 3 times
continuosly
10.3 – WARNING LIGHT
TERMINALS: 11-12.
The warning light is an accessory used for signaling any movement
of the gate door.
It is arranged to connect the FL200 flashing light.
10.4 – CONTACT OF THE AUXILIARY "OUT1" OUTLET
TERMINALS: 1-2.
The OUT1 outlet is a volt-free contact (relay contact). It is enabled
by the transmitter button. An accessory with a maximum voltage
of 24V max 3W can be connected.
10.5 – SAFETY DEVICES
TERMINALS: 4-9-10.
Control unit has two safety inputs available for voltage free (dry
con- tact) connection(s).
"S2 Photo" CLOSING or OPENING/CLOSING PHASE SAFETY
DEVICES
Terminals 4,8 allow connection of safety devices active during
closing and opening phase. This input is normally closed (NC). For
infra-red photocells and safety edges with micro-switch contact.
The factory wire bridge connected to S2 Photo must be removed
when using this input.
These devices intervene during the gate's closing and opening
phase according to DIP switch 4 (see par. 4.1).
In particular:
DIP4 set to ON:
- during the closing phase they invert the movement direction
and re-open the door fully
- during the opening phase they have no effect
- with the opened door they lock closing commands
- with the closed door they have no effect
DIP4 set to OFF:
- during the closing phase they lock the movement and re-open
the door fully when released
- during the opening phase they lock the movement and re-
open the door fully when released
- with the opened door they lock closing commands
- with the closed door they lock opening commands
Figure 38 show examples "PHR00" photocell connections.
When multiple devices are connected on this contact,

Publicité

loading