10. Assemble the two [P] and [R] stop blocks if they are not as-
sembled.
11. Loosen the screws of the two mechanical stops, then move
the front mechanical stop [P] in front of the carriage (fig. 22).
Q
22
3.2.4 – PHR00 photocells (optional)
Caution: disconnect the power supply to the system before
performing any installation operations.
• position each photocell 40/60 cm above the ground
• position them on the opposite sides of the zone to be
protected • position them as close as possible to the
door (maximum distance = 15 cm) • a tube for passing the
cables must be present in the fastening point • orient the
TX transmitter towards the central zone of the RX receiver
(allowed misalignment: maximum 5°)
01. Remove the front glass (Phase 01 - Fig. 23)
02. Remove the upper casing then the internal casing of the pho-
tocell (Phase 02 - Fig. 23)
03. Perforate the lower casing in the point where the cables
should pass (Phase 03 - Fig. 23)
23
01.
04.
P
02.
05.
Ø 3,5 mm
˜
12. Push the carriage in the closing direction and, on reaching the
position, tighten the screw [Q] fully down.
13. Manually open the door to the required opening position,
move the rear mechanical stop [R] next to the carriage (fig. 23)
and tighten the screw [Q] fully down. Important! - Make sure the
release cord can be pulled below a height of 1.8 m.
23
R
Q
04. - Position the lower casing in the point where the tube for the
passage of the cables arrives and mark the perforation points
(Phase 04 - Fig. 23)
- Use a percussion drill to drill the wall with a 5 mm bit. Insert
the 5 mm wall plugs (Phase 04 - Fig. 23)
- Pass the electrical cables through the relevant holes and
fasten the lower casing with the screws (Phase 04 - Fig. 23)
05. - Connect the electrical cable to the appropriate terminals
both to the TX and RX photocells (Phase 05 - Fig. 23). Carry
out the electrical connections according to the required fun-
ction and figure 38.
- Put back in place, in the following order, the inner casing
followed by the upper casing to be fastened with the two
screws then, lastly, insert the cover and exert slight pressure
to close it (Phase 05 - Fig. 23).
03.
1
Led SAFE
2
3
4
English – 11