Picture 8 - Predisposition of the smoke outlet
This connector allows a tolerance of about 1
cm in order to make the installation easier.
The tolerance is available according to a sin-
2 mm
Picture 9 - Tolerance for smoke outlet on the top or rear. The tolerance depends on the orientation of the conjunction.
2.6
Zona di
Zona di
Comignolo
Schornsteinaufsatz
reflusso
reflusso
The exchange of air must be ensured in the
place in which the cooker is installed, special-
Canna
Canna
ly if the room is small and the windows and
fumaria
fumaria
door frames have hermetical closure. The
rdo o
Raccordo o
Raccordo o
da fumo
canale da fumo
canale da fumo
2.7
Termocucina
Termocucina
Termocucina
For ST 90 model, the connection to AC pow-
er for the thermal cookers with oven must
be done by experienced people according
to local laws. The installer is responsible for
the correct connection according to safety
rules. To make the connection you have to
connect a network cable to the terminal
board situated in the rear of the kitchen.
+/-
10 mm

VENTILATION

Zona di
Schornsteinaufsatz
Schornsteinaufsatz
Windfangbereich
reflusso
Rauchabzugsrohr
Rauchabzugsrohr
Rauchrohrstutzen
Rauchrohrstutzen
oder -kanal
oder -kanal
ELECTRIC CONNECTIONS (ST 90)
Zentralheizungsherd
gle direction that depends on the orientation
of the connector (see picture 9).
+/-
+/-
Y
Y
10 mm
10 mm
Chimney
Chimney
Windfangbereich
Windfangbereich
flow of air must be ensured also in presence
of other combustion devices, aspiring hoods,
Flue
Rauchabzugsrohr
chimneys or vent-holes. The air intake must
have a minimum surface of 80 cm².
Rauchrohrstutzen
Conjunction
oder -kanal
Zentralheizungsherd
Zentralheizungsherd
In addition to the phase connection, it is
obligatory the earthing of the device. The
cable and the other electrical devices must
be dimensioned for the electrical charge to
sustain and must not touch points 50° hot-
ter than the ambient temperature (picture
10).
64
40 mm
X
Y
Reflow
Reflow
Chimney
Souche
zone
zone
Flue
Flue
Conjunction
Conjunction
Thermal cooker
Thermal cooker
Thermal cooker
X
X
+/-
+/-
+/
10 mm
10 mm
10 m
Reflow
Zone de
Souche
Souche
zone
refoulement
Conduit
Conduit
de fumées
de fumées
Tuyau de raccordement
Tuyau de racco
ou carneau
ou carne
Thermo cuisinière
Therm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

St 60St 90

Table des Matières