Chimney has a main importance for the
correct working of a wood fired thermal
cooker. The thermal cookers work at their
best only if the chimney matches the build-
ing laws. Call an experienced technician or
a local chimney-sweeper for every problem
14
Windfangbereich
13
12
11
ohr
tzen
al
lheizungsherd
Windfangbereich
Picture 4 - The parts of the chimney
uchabzugsrohr
2.3
chrohrstutzen
oder -kanal
Chimney must match the existing laws. For
ST 60 the diameter of the exhaust-pipe
Holzherd
should be 15 or 16 cm. For ST 90 the diam-
eter of the exhaust-pipe should be 16 or 18
cm. The connection to a flue shorter than 4
m is not allowed. The thermal cooker must
NO
Picture 5 - Examples of correct and uncorrect chimney execution
CHIMNEY
Chimney
Chimney
DIMENSIONS AND CORRECT FORMS OF CHIMNEY
dealing the chimney, the exhaust-pipe and
connection with the thermal cooker.
Reflow
zone
Flue
Conjunction
Thermal cooker
Reflow
zone
Flue
Conjunction
not be connected to a shared flue, moreover
the connection should be linear as more as
Cooker
possible, without horizontal parts (see pic-
ture 5).
YES
62
X
+/-
10 mm
Souche
Souche
Conduit
de fumées
Tuyau de raccordem
ou carneau
Cuisinière