Alarm
Fault
No water in chamber, or water
H2O
pressure too low.
No water at drain, or water
H2O.
pressure too low
There is no water in the cham-
H2OL
ber or there is insuffi cient wa-
ter pressure during washing.
There is no drain water, or
H2OL.
there is insuffi cient water pres-
sure during washing.
No mains gas, gas pressure too
E12
low or fl ame detection failure.
Oven door opening or closure
OPE
request.
At oven switch-on: Indicates
CLE
that cleaning is required.
At oven switch-on: Indicates
CAL
the need for the descaling op-
eration.
The cooking chamber probe
E01
has failed or is not properly
connected.
The core probe has a failure
E02
or has not been properly con-
nected.
The steam discharge probe
E03
has failed.
The motor-operated valve is
E04
not positioned correctly.
E05
Safety thermostat failure.
E06
Overload cutouts tripped.
E07
Power board failure
The optional vacuum probe
E08
has failed or is not properly
connected.
Maximum allowed temperatu-
E09
re in chamber exceeded.
3354462_ATG_ut_GB
Remedy
Check that mains water is pre-
sen, if the problem persists in-
form the after-sales service.
Check that mains water is pre-
sen, if the problem persists in-
form the after-sales service.
Check that mains water is pre-
sent; if the problem persists in-
form the after-sales service.
Check that mains water is pre-
sent; if the problem persists in-
form the after-sales service.
Press RESET (the button may
have to be pressed several
times), if the problem persists
inform the after-sales service.
Open or close the oven door
Inform the after-sales service
if this message continues to be
displayed.
Perform a washing program.
Perform descaling.
Inform the after-sales service.
Check the position of the pro-
duct core probe or inform the
after-sales service if it is faulty.
Inform the after-sales service.
Switch on the oven again and
if the problem persists inform
the after-sales service.
Inform the after-sales service.
Inform the after-sales service.
Inform the after-sales service.
Press RESET.
Inform the after-sales service.
- 37 -
Notes
Convection cooking cycles can
still be carried out
Convection and steam coo-
king cycles can still be carried
out
Cooking cycles can be carried
out..
It is not possible to run cook-
ing cycles until an entire wash
cycle or emergency rinse has
been carried out.
Stop cooking if this message is
repeated more than once.
The cooking cycle does not
start until the door has been
opened or closed as required.
Normal operation of the oven
depends on the "Oven clean-
ing time limit OFF/ON" setting.
The oven's functions are ena-
bled so cooking cycles can be
carried out.
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
Cooking cycles with product
core probe cannot be carried
out.
Convection and steam coo-
king cycles can still be carried
out.
Convection and steam coo-
king cycles can still be carried
out.
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
The oven's functions are disa-
bled so no cooking cycles can
be carried out
Disconnect and reconnect the
vacuum probe before starting
the cooking cycle.
If the problem persists, call the
after-sales service.
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
GB
ENGLISH