14.3
Technical specifications "Overview tables"
14.3.1
Electrical data
Description
Supply voltage
max. power consumption
IN 115 V 50/60 Hz
230 V 50/60 Hz
Motor power 115 V / 230 V
50/60 Hz
Fuse rating
Type of protection
Breaking capacity at circuit
with 24 V
Breaking capacity at circuit
with 230 V
14.3.2
General data
Description
Pump output [l/h]*/**
max. metering backpressure [MPa
(bar)]
Piston diameter [mm]
Number of strokes [1/min] at 50 Hz
Metering quantity/stroke [cm³] 50
Hz/60 Hz
exactness of reproduction
14.7 'Metering rates' on page 128
max. conveyable viscosity [mPas]
Permitted ambient temperature
Suction height [mWs] at 100 %
stroke***
max. pre-pressure (suction side)
[MPa (bar)]
Noise level (DBA) in 1 m distance
(according to DIN EN 12639/ EN ISO
9614-2)
Hose connectors Suction-/Return line
[ID mm]
Hose connectors
Pressure(metering)line [ID mm]
Weight [kg]
* all data relate to water at 20 °C.
** At a mains power frequency of 60 Hz, the delivery capacity increases by 20%, while the
metering backpressure decreases by 20%.
*** Suction heights with clean, moistened valves at 100% metering stroke and max. stroke
frequency.
Pump type
00002
00005
Empty report output: 24 V 3 A AC/DC
stroke signal output: 24 V 0,3 A DC
connection according to VDE is not permitted!
Pump type
00002
00005
0,2
3
0,027 /
0,032
Ä Chapter
2/4
123
Technical Specifications
00009
230 V / 50/60 Hz ± 10 %
(special voltages on request)
0,2 / 0,21 A
0,09 A
18,7 / 19,8 W
315 mA
IP 65
Empty report output:
230 V / 3 A AC/DC
stroke signal output:
00009
0,5
0,9
1 (10)
4,76
6,34
122
0,068 / 0,082
0,12 / 0,44
< ± 3%
200
5-40°C
2
0,03 (0,3)
54
6/8, 6/10, 6/12
4/6
2,4
417101442 Rev. 12-02.2019
00014
00014
1,4
8
0,19 / 0,23