WARNING!
The installation must only be performed by authorized personnel and the
general guidelines and local installation regulations must be observed!
– The metering pump should be fitted in an easy-to-access, frost-free
location.
The ambient temperature must not exceed +40° C.
– The mounting position of the device must be horizontal.
– The pump must be securely screwed to the bracket or the container using
the drill holes provided (
6.1

Mounting diagram

NOTICE!
The pump must be screwed firmly to the console or container using the holes
provided for this purpose (hole spacing
on page 122).
Fig. 7: Mounting diagram
1
pressure relief valve
2
metering valve / pressure control valve
The metering valve, pressure control valve and pressure relief valve can be
replaced by a multifunction valve (MFV) from our product range, which
combines all of these functionalities.
Ä Chapter 14.2 'Dimensions' on page 122).
Ä Chapter 14.2 'Dimensions'
3
suction pipe / bottom admission valve
31

Mounting

417101442 Rev. 12-02.2019