Technical Specifications "Overview Tables; Electrical Data; General Data - Standard Pumps; Pumps In The "Higher Pressures (Hp)" Versions - Ecolab Elados EMP III E60 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14.3

Technical specifications "Overview tables"

14.3.1

Electrical data

Description
Supply voltage
max. power consumption I
max. starting current I
Motor power
Fuse rating
Type of protection
Breaking capacity at circuit with 24 V
Breaking capacity at circuit with 230 V
14.3.2

General data - Standard pumps

Description
pump output [l/h]
max. metering backpressure [MPa
max. permissible pre-pressure [bar]
number of strokes [1/min] at 50 Hz
metering quantity/stroke [cm³]
metering accuracy [see chapter 14.6]
max. conveyable viscosity [mPas]
permitted ambient temperature
suction height [mWs] at 100 %
max. pre-pressure (suction side) [MPa (bars)]
noise level [DBA] at 1 m distance
(acc. to DIN EN 12639/ EN ISO 9614-2)
recommended minimum diameter of suction/pressure
connector [ID mm]
weight [kg]
*
All data relate to water at 20 °C
**
At mains power frequency of 60 Hz, the delivery capacity increases by 20%, while metering backpressure decreases by
20%.
***
Suction heights with clean, moistened valves at 100% metering stroke and max. stroke frequency
CAUTION
14.3.3

Pumps in the "Higher Pressures (HP)" versions

Description
pump output
[l/h]*
max. metering backpressure [MPa (bar)]
metering quantity/stroke [cm³]
*
all data relate to water at 20 °C
417101441_EMP_III_E60.docx
115V 50/60 Hz
N
230V 50/60 Hz
3PE 400V 50 / 60 Hz
(I
 3,3)
A
N
115V 50/60 Hz
230V 50/60 Hz
3PE 400V 50 / 60 Hz
115V 50/60 Hz
230V 50/60 Hz
3PE 400V 50 / 60 Hz
115 V
230 V
empty report output
stroke signal output
empty report output
stroke signal output
*/**
(bars)]**
stroke***
Regarding DIN EN 809 5.2.3, we point out that the temperature on the motor can become
higher than 80°C. The contact with this area should therefore be avoided during operation.
00160
00250
230 V/50/60 Hz ± 6% - 10%
(special voltages on request)
24 V 3 A AC/DC
24 V 0,3 A DC
230 V / 3 A AC/DC
connection according to VDE is not permitted
00160
00250
16
25
1 (10)
0,8
2,1
3,4
6 mm
PVC tube 6/12, 10/16
7,4
Pump type
00160
14,7
1.6 (16)
1,98
- 130 -
Pump type
00540
00800
01200
1,6 / 1,8 A
0,8 / 0,9 A
0,48 / 0,43 A
5,3 / 5,9 A
2,6 / 3 A
1,6 / 1,4 A
0,09 kW
0,09 kW
0,09 kW
4A
2A
IP 55
Pump type
00540
00800
01200
54
80
0.4 (4)
0.3 (3)
0,6
122
7,3
10,8
16,1
<  3%
200
5-40°C
2
0.05 (0.5)
48,0
12 mm
PVC tube 12/21
8,6
00250
23,5
1.2 (12)
3,15
Rev. 13-10.19
120