Menu description
10.3.13.5 Metering monitoring / Input (only at E60 WITHOUT Dongle box)
The "Input" setting is used to determine which input (pulse input or metering lock) at plug
II (or at plug V, if a dongle box is used)of the pump should be used to evaluate the
incoming pulses from the metering monitoring unit.
The flow monitor connection depends on the selected input:
Input pulse:
Input metering lock:
NOTICE!
This function can only be selected if no dongle box is connected. In this case,
the original function (e.g. pulse input)can no longer be used.
Fig. 63: Metering monitoring / Input (only at E60 WITHOUT Dongle box)
10.3.13.6 Oval gear meter pulse display (only E60
Oval gear meter pulse display (only
417101442 Rev. 12-02.2019
plug II (or plug V) Pin 2+4
,
plug II (or plug V) Pin 3+4
This display shows the number of pulses recorded during the last
calibration process (running time during calibration: 1 min).
If the value shown is less than 60, metering monitoring using an
oval gear meter is only possible to a limited extent.
E60
PLUS
)
Ä Chapter 7.2.3.5 'Installing the metering
monitoring ' on page 43.
PLUS
)
86