Installation instructions, for professionals only
5.9. Connecting humidity sensor FTS2
(optional, only Pro D3/Pro D3i)
1. Feed the wires for the sensor through the cable gland 4 into the low-voltage
connection area 1.
2. Connect the wires for the temperature sensor to the terminals labelled "F2"
in terminal strip 2.
a. Connect the black wire to the right terminal.
b. Connect the brown wire to the left terminal.
3. Connect the wires for the humidity sensor to the terminals labelled "+ S -"
in terminal strip 2.
c. Connect the green wire to terminal "+".
d. Connect the orange wire to terminal "S".
e. Connect the red wire to terminal "-".
5.10. Connecting foil sensor (optional, only Pro D2i/Pro D3i)
1. Feed the wires for the sensor through the cable gland 4 into the low-voltage
connection area 1.
2. Connect the sensor cables for the sensor to the terminals labelled "FF"
in terminal strip 2.
5.11. Connecting the safety cut-out
EN 60335-2-53 states that sauna control units with a remote start or preset timer
function may only be used for operating and regulating a sauna heater which
has satisfied the combustion test described in paragraph 19.101. Alternatively,
a suitable safety cut-out device can be installed in or above the heater. This shuts
the sauna heater off if items such as a towel are placed on the sauna heater.