16. Technical data

16.1. Power unit

Ambient conditions

Storage temperature:
Ambient temperature:
Relative humidity:
Sauna control unit
Dimensions (W x H x D):
Switched voltage/three-phase 3N:
Frequency:
Contact rating/heater:
Switched current per phase/heater:
Switching capacity/evaporator (only Pro D3/Pro D3i): 3.5 kW
Switched current/evaporator (only Pro D3/Pro D3i):
Switching capacity/additional output (dimmable)*
Switching capacity/additional output (switchable)*
Switched current/additional output*:
Status output:
Rated voltage:
Enclosure rating (protected against splashing water): IPX4
Connection to the mains supply as fixed wiring (fixed connection)
Light
Switching capacity:
Fuse:
Fan
Switching capacity:
Fuse:
* Only the Pro D2i/Pro D3i models have an additional output. The additional out-
put has no overheat cut-out. For this reason, only intrinsically safe appliances
should be operated using the additional output.
WORLD OF WELLNESS
p. 68/70
-25 °C to +70 °C
-10 °C to +40 °C
max. 95%
307 x 175 x 57 mm
400 V AC
50 Hz
3 x 3.5 kW
16 A
16 A
500 W
3.5 W
16 A
24 V/200 mA
230 V
100 W
1A T
100 W
1A T