Installation instructions, for professionals only
Activating the simultaneous display of the temperature and the humidity
(only Pro D3/Pro D3i)
To activate simultaneous display (automatic switching between the temperature
and humidity display) of the temperature and humidity, carry out the following steps:
1. Open the technician menu (see Page 39).
2. Select "dUA" by pressing the mode button D.
3. Press the On/Off button A.
4. Select the desired setting using the plus button B and the minus button C.
● "oFF" means the display stays at the selected function (standard)
● "on" means the display switches between temperature and humidity
automatically
5. Confirm the selection by pressing the On/Off button A.
6. Make other settings or leave the technician menu by pressing the On/Off
button A for about 3 seconds.
7. Then switch the power unit off for about 10 seconds.
Status output (only Pro D3/Pro D3i)
You can decide here whether the status output should be activated during sauna
mode or during the post-drying program. Activation during the post-drying program
allows the evaporator to be drained automatically when a combi heater with an
auto refill function is being used. Then perform the following steps:
1. Open the technician menu (see Page 39).
2. Select "SL" by pressing the mode button D.
3. Press the On/Off button A.
4. Select the desired setting using the plus button B and the minus button C.
● "oFF" the status output is activated during the sauna operation (standard)
● "on" the status output is activated during the post-drying program
5. Confirm the selection by pressing the On/Off button A.
6. Make other settings or leave the technician menu by pressing the On/Off
button A for about 3 seconds.
7. Then switch the power unit off for about 10 seconds.
WORLD OF WELLNESS
p. 43/70
EN