Sentiotec Pro D Serie Instructions D'installation Et D'utilisation page 83

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Instructions for installation and use
● Optional dimming or switching of a cublicle light (up to 100 W)
● Optional dimmer function or control of a fan (up to 100 W)
● Remote start function
● Status output
● Preset time function (up to 6 hours)
● User programs
The user programs enable favourite sauna settings to be saved and accessed
again. There are 5 preset user programs available which can be modified
according to user requirements.
● Automatic heating period limiter
The sauna control unit shuts down automatically after the maximum heating
period for safety reasons. The maximum heating period can be set to 6 h,
12 h, 18 h or 24 h.
● Post-drying program
Once combi-mode has finished, the post-drying program starts automatically
to prevent mould or rot from forming in the sauna room. This involves heating
the sauna room to 80 °C with the fan running for 30 minutes.
● Overheat cut-out
The overheat cut-out is installed in the housing for the heater sensor. Should
the sauna heater continue heating after reaching the preferred temperature
due to a defect, the overheat cut-out switches the sauna heater off at a tem-
perature of approx. 139 °C.
Pro D3i/Pro D3i white
Same functional scope as the Pro D3/Pro D3 white, however with further additions:
● Additional output
Either for dimming (up to 500 W), switching (up to 3.5 kW) or regulating
the sauna room temperature via the additional output.
The additional output has no overheat cut-out. For this reason, only intrinsi-
cally safe appliances should be operated using the additional output.