Quick Programming - Roco multiZENTRALEPRO Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.8 Quick programming

The most important decoder settings for drive mode, known as configuration variables � CVs, can be made
using the combination of "MENU" + "function key."
CV Function
1
Locomotive address
Note: A change to this value has a direct effect on the decoder but not on the
locomotive library. The address saved there has to have the same value as the
CV.
2
Minimum speed
3
Acceleration
4
Braking time
5
Maximum speed
8
Resetting all decoder data to factory values (please read the decoder manual).
Quick programming is possible in both „library mode" and "locomotive address mode". All changes to CVs 1–5
only have an effect on the locomotive in digital operation. It is basically possible to enter values between 1 and
255 (locomotive address up to 9,999, read Part 3 "Menus" for details about addresses above 100!). Since each
decoder and each CV requires specific values, please consult the corresponding decoder manual.
ROCO decoders already installed in locomotives are delivered with suitable settings. Check before perform-
ing programming whether it is really necessary.
Programming must be carried out on a separate programming track unless only one other digital locomotive
or one turnout decoder is connected via the tracks or another type or wiring with the multiZENTRALE
if the multiMAUS
If programming is carried out on the regular track and if more than one digital locomotive is located on that
track (or turnout decoders other than the ROCO articles 42624 and 10775), the settings of all decoders in
the system are changed with one programming command. This means it is possible to accidentally change
all decoders to the same locomotive address, for example.
The programming track must be electrically insulated completely from the remaining system and
is connected to the programming track connection of the multiZENTRALE
"multiZENTRALE
Example: To program the locomotive address = CV1 to value 4:
Input
64
64
is set to "POM" mode (see Part 3 "Menus").
PRO
" for additional details.
PRO
Display message
PRO
Comment
The display indicates the selected CV first (displayed
as "C 1") and then switches to displaying the read
value. Values are not displayed in "POM" mode (Part
3 "Menus").
keys
+
+
+
+
+
+
or
PRO
. Please read Part 4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Multimauspro108121083010832

Table des Matières