9.2. Programming automatic closing

To programme automatic closing, use the PAUSA and PROG
buttons of the control unit.
9.2.1. activating automatic closing
(max timer 120s)
[1]. With the control unit powered and the gate closed (FCC LED
off), press the PROG button.
The DL 10 LED will flash to indicate that the control unit is in
programming mode.
[2]. Press and hold the PAUSA button until the contacts «click».
The indicator will come on.
The control unit will start counting the seconds (indicated by
the intermittent flashing of the indicator) for the automatic
gate closure delay.
[3]. Press the PAUSA button when the required time is reached.
The control logic will memorise the time elapsed between the
two presses of the PAUSA button.
The automatic closure delay of the gate is programmed.
Note: if the PAUSA button is not pressed a second time, the
control unit will automatically exit the programming mode after
120 seconds and store the maximum time of 120 seconds for the
automatic closing delay.

9.2.2. deactivating automatic closing

[1]. With the control unit powered and the gate closed (FCC LED
off), press the PROG button.
The DL 10 LED will flash to indicate that the control unit is in
programming mode.
[2]. Press and hold the PAUSA button until the DL10 LED goes out.
The control unit will exit the programming phase, automatic
closing is deactivated.

9.3. setting inputs 18 and 19

To set the parameters for inputs 18 and 19, use the PAUSA,
LAVORO and PROG buttons of the control unit.

9.3.1. setting input 18

to have input 18 in oPEN only:
[1]. Disconnect the control unit.
[2]. Press the PROG, LAVORO and PAUSA buttons at the same time and then reconnect the control logic while keeping the
buttons pressed.
to switch input 18 back to PEdEstriaN oPEN/ClosE:
[1]. Disconnect the control unit.
[2]. Press the LAVORO and PAUSA buttons at the same time and then reconnect the control logic while keeping the buttons pressed.
9.3.2. setting input 19
to have input 19 in ClosE only:
[1]. Disconnect the control unit.
[2]. Press the PROG and PAUSA buttons at the same time and then reconnect the control logic while keeping the buttons
pressed.
to switch input 19 back to oPEN/ClosE:
[1]. Disconnect the control unit.
[2]. Press the PROG and LAVORO buttons at the same time and then reconnect the control logic while keeping the buttons pressed.
Copyright © 2011 Somfy SAS. All rights reserved.
PAUSA
LAVOR
LAVOR
A A
O
O
PROG
20
20
19
19
START
START
18
18
PED
PED
STOP
STOP
FOTO
FOTO
FCA
FCA
PAUSA LAVORO PROG
PAUSA LAVORO PROG
DL10
DL10
FCC
FCC
[1]
COSTA
COSTA
10
10
9
9
DL10
DL10
PAUSA LAVORO PROG
PAUSA LAVORO PROG
DL10
8
8
[2]
7
7
6
6
5
5
DL10
4
4
3
3
F1
F1
2
2
PAUSA LAVORO PROG
[3]
1
1
DL10
PAUSA LAVORO PROG
PAUSA LAVORO PROG
[1]
DL10
DL10
PAUSA LAVORO PROG
PAUSA LAVORO PROG
[2]
DL10
DL10
PAUSA
LAVOR
O
PROG
20
20
19
19
START
START
18
18
PED
PED
STOP
STOP
FOTO
FOTO
FCA
FCA
DL10
DL10
FCC
FCC
COSTA
COSTA
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
F1
F1
2
2
1
1
Elixo 800/1300/2000
DL12
DL12
PROG
PROG
F2
F2
DL11
DL11
...
DL12
DL12
PROG
PROG
F2
F2
DL11
DL11
15

Publicité