3.5. Control unit description

3.5.1. Control unit

item
2
C INDICATOR
nd
MR/08 SR 24.08 MODULE
SOG/4A
ENCODER
SW1
SW2
PROG
LAVORO
PAUSA
REG
RTS RADIO MODULE
PROG

3.5.2. indicator lights

indicator
function
light
START
Open/close control
PED
Pedestrian open control
STOP
Stop control
FOTO
Photoelectric cells
FCA
Opening end limit
FCC
Closing end limit
COSTA
Safety edge
DL10
Programming/test
DL11
Motor control
DL12
Encoder
4
function
Connector for MR/08 relay module
connection
Relay module for gate open indicator
and 2
starter capacitor
nd
Not used
Connector for encoder connection (if
present)
Micro switches for settings
Micro switches for settings
Button to enter motor programming
Working time programming button
Programming button for gate open
pause time/delay before automatic
closing
Potentiometer for setting the motor
force, and detection sensitivity
Module for RTS radio reception
Button to enter remote control
programming, RTS radio control point
on
Open/close control activated
Pedestrian open/close control activated
Stop control in normal state
Cells not obscured - normal state
Gate moving or in intermediate position
(NC switch)
Gate moving or in intermediate position
(NC switch)
Safety edge in normal state
- flashing to indicate programming active
- flashing at high frequency to indicate any faults found in the motor control test
Light intensity different according to the voltage of the motor control
When the gate is moving it indicates that pulses are being received from the encoder
PAUSA LAVORO PROG
20
19
START
18
PED
17
16
STOP
15
FOTO
14
13
FCA
DL10
12
FCC
11
COSTA
10
9
DL11
8
7
6
5
4
3
F1
2
1
fusEs:
FUSIBLES :
F1 = 5A 250V~ - instantané -
f1 = 5a 250v~ -quick-break-
230v power supply protection
protection alimentation 230V
f2 = t1, 6a 250v~ -delay-
mr/08 rElay
F2 = T1,6A 250V~ -retardé-
low voltage protection
MODULE MR/08
modulE
protection basse tension
off
not activated - normal state
not activated - normal state
Stop button activated
Cells obstructed - obstacle present
Gate completely open (NO switch)
Gate completely closed (NO switch)
Safety edge in action
Copyright © 2011 Somfy SAS. All rights reserved.
DL12
PROG
F2