sPEcIfIcATION

15.5 Appliance wiring diagram

Wiring diagram
Wiring diagram layout
A1
Electronic charge controller
A4
User interface PCB
Core sensor – charge (at 20 °C ≈ 541 X)
B1
E1-E6 Heating elements
F1
High limit safety cut-out
F2
Fuse (250 2A slow)
K1
Thermal relay
M1
Storage heater fan
N4
Protective thermostat – charge
N5
Protective thermostat – discharge
N6
Protective thermostat only for 3.0-4.8 kW
R1
Adjuster – charge 10 kΩ (rotary selector)
V4
Operating and fault display
X1
Mains terminal
X2
Terminal
X3
DC terminal (0.9 – 1.43 V)
X16
Control signal matching, four-stage
X17
Output reducer, four-stage
www.stiebel-eltron.com
Special accessories
(Not part of the standard delivery. Tick the boxes for each special
accessory installed.)
RTI-E3
RTI-EP2
A2
Electronic discharge control
Room temperature sensor – discharge (at 20 °C ≈ 27.1 kΩ)
B2
R2
Adjuster – discharge 10 kΩ
S2
Room thermostat ON/OFF switch
X25
Internal connecting cable A1-A2
Booster heater
E8
Booster heater
N2
Booster heater thermostat
N3
Booster heater thermostat
S1
Booster heater ON/OFF switch
When installing a booster heater (E8), take the switching output
of the room thermostat into account.