OPErATION
WHAT TO DO If...
»
Hook the upper edge of the air inlet grille into the locking device
screws, and press from below over the catch springs.
Hooking in the air inlet grille
Pressing the catch springs
28
|ETW 120, 180, 240, 300, 360, 420, 480 electronic
6.
What to do if...
fault
cause
The appliance does not
The charge was not set
warm up.
or was set too low.
No power supply.
The heat transfer of the
The setting at the
appliance is too high
charge control system
even in mild weather.
and/or charge controller
is incorrect.
Appliance does not
Fluff filter clogged.
discharge.
Note
Changes or removal of faults at the charge control
system only become apparent after renewed charging.
If you cannot remedy the fault, contact your contractor. To speed
your call for assistance, provide the number on the type plate (no.
XXXXXX-XXXX-XXXXXX):
Type plate example
remedy
»
Set the rotary selector
for the charge
controller higher.
»
Set the charge of
the charge control
system higher (see
charge control
system operating
instructions).
»
Check the MCB/fuse
and RCD in your
fuse box.
»
Adjust the settings.
»
See chapter
"Cleaning, care and
maintenance."
000000
0000
000000
www.stiebel-eltron.com