INsTAllATION

sAfETY

7.
Safety
7.1

Country-specific safety information

All required steps to complete commissioning must be carried out
by a qualified contractor. During this process, these installation
instructions must be observed.
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
7.2

Instructions, standards and regulations

Risk of damage.
!
Observe the type plate. The specified voltage must
match the mains voltage.
Size the equipment according to the rated consumption
of the appliances.
Note
!
Observe the Building and Garage Regulations [or local
regulations].
Danger of electrocution!
All electrical connection and installation work must
be conducted in accordance with VDE regulations
(DIN VDE 0100) [or local regulations], the rules of your
local power supply utility and relevant national and
local regulations.
Danger of electrocution!
Connection to the power supply is only possible as a
permanent connection.
The appliance must be able to be separated from the
mains power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
Important information
!
Secure the appliance to the wall or floor in such a way
as to ensure stability.
8.

Equipment description

8.1

Standard delivery

— Storage heater
— 2-3 wall retainers
— Operating and installation instructions
— Storage blocks
8.2

Factory settings

The appliance connection is wired to the maximum output (100%).
If jumpers at the terminals are moved or removed, the connected
load can be matched.
8.3

Design operation

The storage blocks are heated via the heating elements between
the rows of storage blocks. The charge can be infinitely adjusted
with the charge controller. The start and duration of the charge
time are set by the local power supply utility.
Two integral protective thermostats and a high limit safety
cut-out prevent the appliance overheating. The protective
thermostats switch back on automatically, but the high limit safety
cut-out must be switched back on after the cause of the fault has
www.stiebel-eltron.com
been removed by the contractor, by pressing the button in the
centre of the high limit safety cut-out.
Cutaway
9
8
7
6
5
4
1
Cover panel
2
Heating element
3
Fan (M1)
4
Protective thermostat (N5)
5
Air inlet grille
6
Air outlet grille
7
Insulation
8
Storage blocks
9
Front panel and inner front panel
The stored heat is transferred via a fan, and partially also via the
appliance surface. For this, the room air is drawn in by the fan
through the air inlet grille, and released through the air ducts in
the storage blocks, which heats it. Before the hot air produced in
this way is released via the air outlet grille, it is mixed with cooler
room air via two mixing air dampers, so the expelled air does not
exceed the highest permissible temperature. The position of the
mixing air damper, and thus the mixing ratio of the air, is regulated
via a bi-metal controller.
8.4

Special accessories

— Two-point room temperature controller
— Proportional room temperature controller
— Booster heater
— Rotary selector cap (charge controller)
— Vario panels
— Support panel
ETW 120, 180, 240, 300, 360, 420, 480 electronic |
1
2
3
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Etw 180Etw 240Etw 300Etw 360Etw 420Etw 480