INsTAllATION
sPEcIfIcATION
15. Specification
15.1 Positioning
Installation details
>70
80,5
89
Ø9
* Installation with ground clearance possible; see point
2.4.2 "Securing the appliance with ground clearance using
wall retainers"
Positioning
Width "B"
Weight (with storage blocks)
Clearance "a" (securing to the floor)
Clearance "b" (securing to the wall)
Supply
Output
Test charge
Max. charge P
H
Storage blocks
No. packs (blocks)
Weight of blocks
Booster heater (special accessory)
Output
www.stiebel-eltron.com
B
b
a
ETW 120
ETW 180
mm 580
741
kg 73.5
106
mm 402
563
mm 337.5
498.5
kW 1.2
1.8
kWh 9.6
14.4
kWh 10.8
16.2
pce. 6 (12)
9 (18)
kg 50
76
kW 0.35
0.5
ETW 120, 180, 240, 300, 360, 420, 480 electronic |
53
>100
85
(162)
89
ETW 240
ETW 300
ETW 360
902
1063
1224
137.5
169
201
724
885
1046
659.5
820.5
981.5
3/N/PE ~ 400 V 50 Hz + 1/N/PE ~ 230 V 50 Hz
2.4
3.0
3.6
19.2
24.0
28.8
20.7
25.9
31.3
12 (24)
15 (30)
18 (36)
101
126
151
0.8
1.0
1.2
218
21
ETW 420
ETW 480
1385
1546
232.5
264.5
1207
1368
1142.5
1303.5
4.2
4.8
33.6
38.4
38.8
43.8
21 (42)
24 (48)
176
202
1.5
1.7
39